ArticleJournal of neurogastroenterology and motility2014
High-resolution Impedance Manometry Criteria in the Sitting Position Indicative of Incomplete Bolus Clearance.
Article in Journal of neurogastroenterology and motility, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 1 synthesis or guideline pooled it, 12 citations in OpenAlex.
- Guideline
- Impact of patient position on esophageal motility disorders using high-resolution esophageal manometry with impedance (HREMI): supine versus upright swallows.Esophagus : official journal of the Japan Esophageal Society · 2021Article
- Characteristics of symptomatic belching in patients with belching disorder and patients who exhibit gastroesophageal reflux disease with belching.Journal of neurogastroenterology and motility · 2021Article
- Improving High-resolution Impedance Manometry Using Novel Viscous and Super-viscous Substrates in the Supine and Upright Positions: A Pilot Study.Journal of neurogastroenterology and motility · 2018Article
- Chronic Cough Is Associated With Long Breaks in Esophageal Peristaltic Integrity on High-resolution Manometry.Journal of neurogastroenterology and motility · 2018Article
- Esophageal Acid Clearance During Random Swallowing Is Faster in Patients with Barrett's Esophagus Than in Healthy Controls.Journal of neurogastroenterology and motility · 2016Article
- High-resolution Impedance Manometry after Sleeve Gastrectomy: Increased Intragastric Pressure and Reflux are Frequent Events.Obesity surgery · 2016Article
- How the Body Position Can Influence High-resolution Manometry Results in the Study of Esophageal Dysphagia and Gastroesophageal Reflux Disease.Journal of neurogastroenterology and motility · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
BACKGROUND/
aimsWe used high-resolution impedance manometry (HRIM) to determine the length of breaks on the isobaric contour which would predict incomplete bolus clearance in patients in the sitting position.
methodsIn total, 651 swallows in 71 patients with esophageal symptoms were studied using a solid-state HRIM system in the sitting position. Each swallow was classified as complete or incomplete bolus clearance by impedance criteria and peristaltic integrity was evaluated using 20- and 30-mmHg pressure topography isobaric contours. Correlations between the lengths of the breaks for 20- and 30-mmHg were analyzed.
resultsComplete bolus clearance was observed in 83.3% (542/651) of swallows. Breaks of 3 and 7 cm or less were associated with a bolus clearance of 96.8% on the 20-mmHg and 94.7% on the 30-mmHg isobaric contour, respectively (P < 0.001). The areas under the ROC curves for the 20 and 30 mmHg isobaric contours were 0.900 and 0.950, respectively. The sensitivity and specificity for complete bolus clearance were 75.6% and 89.3% for breaks 3 cm or less on the 20-mmHg isobaric contour and 87.9% and 78.7% for breaks 7 cm or less on the 30-mmHg contour (P < 0.001).
conclusionsBreaks of < 3 cm in the 20-mmHg isobaric contour or < 7 cm in the 30-mmHg isobaric contour were associated with com-plete bolus clearance. The threshold for breaks in the sitting position was greater than previous reports using the supine posi-tion and longer breaks predicted incomplete bolus clearance.(J Neurogastroenterol Motil 2014;20:491-496).
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.