ArticleAnalytical chemistry2014
Microfluidic Western blotting of low-molecular-mass proteins.
Article in Analytical chemistry, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 28 citations in OpenAlex.
- Review
- Controlling the separation of native proteins with temperature in thermal gel transient isotachophoresis.Analytical and bioanalytical chemistry · 2023Article
- Integration of hydrogels into microfluidic devices with porous membranes as scaffolds enables their drying and reconstitution.Biomicrofluidics · 2022Article
- Capillary electrophoresis Western blot using inkjet transfer to membrane.Journal of chromatography. A · 2022Article
- The Intriguing Landscape of Single-Cell Protein Analysis.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2022Review
- Native detection of proteinThe Analyst · 2020Article
- Rapid electrotransfer probing for improved detection sensitivity in in-gel immunoassays.Analytical methods : advancing methods and applications · 2020Article
- Fast Immunoassay for Microfluidic Western Blotting by Direct Deposition of Reagents onto Capture Membrane.Analytical methods : advancing methods and applications · 2020Article
- Controlling Dispersion during Single-Cell Polyacrylamide-Gel Electrophoresis in Open Microfluidic Devices.Analytical chemistry · 2018Article
- Fabrication of an Open Microfluidic Device for Immunoblotting.Analytical chemistry · 2017Article
- Review
- Recent Advances in Microscale Western Blotting.Analytical methods : advancing methods and applications · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
Abstract
We describe a microfluidic Western blot assay (μWestern) using a Tris tricine discontinuous buffer system suitable for analyses of a wide molecular mass range (6.5-116 kDa). The Tris tricine μWestern is completed in an enclosed, straight glass microfluidic channel housing a photopatterned polyacrylamide gel that incorporates a photoactive benzophenone methacrylamide monomer. Upon brief ultraviolet (UV) light exposure, the hydrogel toggles from molecular sieving for size-based separation to a covalent immobilization scaffold for in situ antibody probing. Electrophoresis controls all assay stages, affording purely electronic operation with no pumps or valves needed for fluid control. Electrophoretic introduction of antibody into and along the molecular sieving gel requires that the probe must traverse through (i) a discontinuous gel interface central to the transient isotachophoresis used to achieve high-performance separations and (ii) the full axial length of the separation gel. In-channel antibody probing of small molecular mass species is especially challenging, since the gel must effectively sieve small proteins while permitting effective probing with large-molecular-mass antibodies. To create a well-controlled gel interface, we introduce a fabrication method that relies on a hydrostatic pressure mismatch between the buffer and polymer precursor solution to eliminate the interfacial pore-size control issues that arise when a polymerizing polymer abuts a nonpolymerizing polymer solution. Combined with a new swept antibody probe plug delivery scheme, the Tris tricine μWestern blot enables 40% higher separation resolution as compared to a Tris glycine system, destacking of proteins down to 6.5 kDa, and a 100-fold better signal-to-noise ratio (SNR) for small pore gels, expanding the range of applicable biological targets.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.