ArticleJournal of diabetes and its complications
Factors affecting the success of glucagon delivered during an automated closed-loop system in type 1 diabetes.
Article in Journal of diabetes and its complications. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 25 citations in OpenAlex.
- A Human Glucoregulatory Model for the Rational Design and Evaluation of Diabetes Therapeutics.ACS pharmacology & translational science · 2026Article
- Integrating Multiple Inputs Into an Artificial Pancreas System: Narrative Literature Review.JMIR diabetes · 2022Review
- Vasodilatory effects of glucagon: A possible new approach to enhanced subcutaneous insulin absorption in artificial pancreas devices.Frontiers in bioengineering and biotechnology · 2022Article
- Preference for Subcutaneously Administered Low-Dose Glucagon Versus Orally Administered Glucose for Treatment of Mild Hypoglycemia: A Prospective Survey Study.Diabetes therapy : research, treatment and education of diabetes and related disorders · 2019Article
- A Review of Safety and Design Requirements of the Artificial Pancreas.Annals of biomedical engineering · 2016Review
- Reducing Glucose Variability Due to Meals and Postprandial Exercise in T1DM Using Switched LPV Control: In Silico Studies.Journal of diabetes science and technology · 2016Article
- Artificial Pancreas Device Systems for the Closed-Loop Control of Type 1 Diabetes: What Systems Are in Development?Journal of diabetes science and technology · 2016Review
- Effect of Repeated Glucagon Doses on Hepatic Glycogen in Type 1 Diabetes: Implications for a Bihormonal Closed-Loop System.Diabetes care · 2015Article
- Incorporating an Exercise Detection, Grading, and Hormone Dosing Algorithm Into the Artificial Pancreas Using Accelerometry and Heart Rate.Journal of diabetes science and technology · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
Abstract
backgroundIn bi-hormonal closed-loop systems for treatment of diabetes, glucagon sometimes fails to prevent hypoglycemia. We evaluated glucagon responses during several closed-loop studies to determine factors, such as gain factors, responsible for glucagon success and failure.
methodsWe extracted data from four closed-loop studies, examining blood glucose excursions over the 50min after each glucagon dose and defining hypoglycemic failure as glucose values<60 mg/dl. Secondly, we evaluated hyperglycemic excursions within the same period, where glucose was>180 mg/dl. We evaluated several factors for association with rates of hypoglycemic failure or hyperglycemic excursion. These factors included age, weight, HbA1c, duration of diabetes, gender, automation of glucagon delivery, glucagon dose, proportional and derivative errors (PE and DE), insulin on board (IOB), night vs. day delivery, and point sensor accuracy.
resultsWe analyzed a total of 251 glucagon deliveries during 59 closed-loop experiments performed on 48 subjects. Glucagon successfully maintained glucose within target (60-180 mg/dl) in 195 (78%) of instances with 40 (16%) hypoglycemic failures and 16 (6%) hyperglycemic excursions. A multivariate logistic regression model identified PE (p<0.001), DE (p<0.001), and IOB (p<0.001) as significant determinants of success in terms of avoiding hypoglycemia. Using a model of glucagon absorption and action, simulations suggested that the success rate for glucagon would be improved by giving an additional 0.8μg/kg.
conclusionWe conclude that glucagon fails to prevent hypoglycemia when it is given at a low glucose threshold and when glucose is falling steeply. We also confirm that high IOB significantly increases the risk for glucagon failures. Tuning of glucagon subsystem parameters may help reduce this risk.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials