ArticleJournal of biomedical optics2014
Measuring protein dynamics in live cells: protocols and practical considerations for fluorescence fluctuation microscopy.
Article in Journal of biomedical optics, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed.
- Characterising C-X-C Chemokine Receptor 4 Dynamics in the Cell Membrane Using Fluorescence Fluctuation Spectroscopy.Biomolecules · 2026Article
- Thermosensory reconfiguration of the auxin transcriptional pathway to drive root cell growth.Nature communications · 2026Article
- Dectin-1 multimerization and signaling depends on fungal β-glucan structure and exposure.Biophysical journal · 2023Article
- A Multiscale Molecular Dynamic Analysis Reveals the Effect of Sialylation on EGFR Clustering in a CRISPR/Cas9-Derived Model.International journal of molecular sciences · 2022Article
- Combined FCS and PCH Analysis to Quantify Protein Dimerization in Living Cells.International journal of molecular sciences · 2021Article
- Empirical Bayes method using surrounding pixel information for number and brightness analysis.Biophysical journal · 2021Article
- GFP fluorescence tagging alters dynamin-related protein 1 oligomerization dynamics and creates disassembly-refractory puncta to mediate mitochondrial fission.Scientific reports · 2020Article
- Determination of oligomerization state of Drp1 protein in living cells at nanomolar concentrations.Scientific reports · 2019Article
- Using enhanced number and brightness to measure protein oligomerization dynamics in live cells.Nature protocols · 2019Article
- Imaging dynamic and selective low-complexity domain interactions that control gene transcription.Science (New York, N.Y.) · 2018Article
- Fission yeast Myo2: Molecular organization and diffusion in the cytoplasm.Cytoskeleton (Hoboken, N.J.) · 2018Article
- Folding Landscape of Mutant Huntingtin Exon1: Diffusible Multimers, Oligomers and Fibrils, and No Detectable Monomer.PloS one · 2016Article
- Regulation of oligomeric organization of the serotonin 5-hydroxytryptamine 2C (5-HT2C) receptor observed by spatial intensity distribution analysis.The Journal of biological chemistry · 2015Article
- Lipid-specific oligomerization of the Marburg virus matrix protein VP40 is regulated by two distinct interfaces for virion assembly.The Journal of biological chemistryArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
Abstract
Quantitative analysis of protein complex stoichiometries and mobilities are critical for elucidating the mechanisms that regulate cellular pathways. Fluorescence fluctuation spectroscopy (FFS) techniques can measure protein dynamics, such as diffusion coefficients and formation of complexes, with extraordinary precision and sensitivity. Complete calibration and characterization of the microscope instrument is necessary in order to avoid artifacts during data acquisition and to capitalize on the full capabilities of FFS techniques. We provide an overview of the theory behind FFS techniques, discuss calibration procedures, provide protocols, and give practical considerations for performing FFS experiments. One important parameter recovered from FFS measurements is the relative molecular brightness that can correlate with oligomerization. Three methods for measuring molecular brightness (fluorescence correlation spectroscopy, photon-counting histogram, and number and brightness analysis) recover similar values when measuring samples under ideal conditions in vitro. However, examples are given illustrating that these different methods used for calculating molecular brightness of fluorescent molecules in cells are not always equivalent. Methods relying on spot measurements are more prone to bleaching and movement artifacts that can lead to underestimation of brightness values. We advocate for the use of multiple FFS techniques to study molecular brightnesses to overcome and compliment limitations of individual techniques.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.