Evidence map›Paper›PMID 25239506›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2016

Computer-assisted navigation is beneficial both in primary and revision surgery with modular rotating-hinge knee arthroplasty.

Björn G Ochs, Anna J Schreiner, Peter M de Zwart, Ulrich Stöckle, Christoph Emanuel Gonser

Abstract read
PubMed Publisher
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Article
  7. Accuracy assessment of target tracking using two 5-degrees-of-freedom wireless transponders.International journal of computer assisted radiology and surgery · 2020
    Article
  8. Accuracy assessment of wireless transponder tracking in the operating room environment.International journal of computer assisted radiology and surgery · 2018
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Björn G OchsBG Trauma Centre, Eberhard Karls University of Tübingen, Schnarrenbergstraße 95, 72076, Tübingen, Germany.
Anna J SchreinerBG Trauma Centre, Eberhard Karls University of Tübingen, Schnarrenbergstraße 95, 72076, Tübingen, Germany.
Peter M de ZwartBG Trauma Centre, Eberhard Karls University of Tübingen, Schnarrenbergstraße 95, 72076, Tübingen, Germany.
Ulrich StöckleBG Trauma Centre, Eberhard Karls University of Tübingen, Schnarrenbergstraße 95, 72076, Tübingen, Germany.
Christoph Emanuel GonserBG Trauma Centre, Eberhard Karls University of Tübingen, Schnarrenbergstraße 95, 72076, Tübingen, Germany. ChrGonser@aol.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe objective of the present study was to explore the effect of navigation on the reconstruction of the mechanical leg axis, implant positioning and the restoration of the joint line in hinged knee arthroplasty in vivo. We present the first 1- to 3-year clinical and radiological results following computer-navigated implantation of the EnduRo modular rotating-hinge knee arthroplasty system (Aesculap AG, Tuttlingen, Germany) as a primary or revision implant.

methodsThirty-one patients were analysed retrospectively. Indication was revision surgery in 18 patients and complex primary surgery in 13. The clinical and radiological results of 31 patients with a minimum follow-up of 12 months (mean 22.2 ± 6.2 months) were recorded. Age at follow-up was 55.2 ± 9.9 years.

resultsThe absolute varus-valgus deviation from the neutral mechanical leg axis was determined at 5.1° ± 5.1° preoperatively and 2.1° ± 1.4° postoperatively. No intraoperative complications or problems with the navigation system were observed. At latest follow-up, no component loosening was detected. Based on the Knee Society Score, a knee score of 64.9 ± 17.7 points and a function score of 67.2 ± 27.3 points were achieved.

conclusionsEncouraging short-term clinical and radiological results with the computer-navigated implantation of the modular rotating-hinge EnduRo knee arthroplasty system were found in both primary and revision surgery. The navigation facilitated the reconstruction of the leg axis, implant positioning and the restoration of the joint line. LEVEL OF EVIDENCE: IV.

Indexed as

Knee ProsthesisSurgery, Computer-AssistedAdultAgedArthroplasty, Replacement, KneeHumansKnee JointMiddle AgedProsthesis DesignRadiographyReoperationRetrospective StudiesStereotaxic TechniquesTreatment OutcomeComputer-assisted surgeryEnduRoKnee replacementNavigationRevision knee arthroplastyRotating-hinge knee

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.