ArticleTranslational vision science & technology2014
Assessment of Central Retinal Sensitivity Employing Two Types of Microperimetry Devices.
Article in Translational vision science & technology, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- Structure-Function Correlation in Patients With Central Serous Chorioretinopathy During Initial Disease Activity and After Ten Years.Investigative ophthalmology & visual science · 2026Article
- Visual Function Assessment in Geographic Atrophy: A Review.Clinical & experimental ophthalmology · 2026Review
- Role of microperimetry to detect early visual function deficits in patients with hydroxychloroquine retinal toxicity-a review.Eye (London, England) · 2025Review
- Inter and intradevice assessment of microperimetry testing in aging eyes.Scientific reports · 2024Article
- Investigating the Spatiotemporal Summation of Perimetric Stimuli in Dry Age-Related Macular Degeneration.Translational vision science & technology · 2023Article
- Calculation of test-retest variability in phase I/IIa clinical trials for Inherited Retinal Degenerations.Ophthalmic genetics · 2021Article
- Fundus-controlled perimetry (microperimetry): Application as outcome measure in clinical trials.Progress in retinal and eye research · 2021Review
- Clinical Perspectives and Trends: Microperimetry as a Trial Endpoint in Retinal Disease.Ophthalmologica. Journal international d'ophtalmologie. International journal of ophthalmology. Zeitschrift fur Augenheilkunde · 2021Review
- Structure-Function Analysis in Macular Drusen With Mesopic and Scotopic Microperimetry.Translational vision science & technology · 2020Article
- Regional Variations and Intra-/Intersession Repeatability for Scotopic Sensitivity in Normal Controls and Patients With Inherited Retinal Degenerations.Investigative ophthalmology & visual science · 2019Article
- Microperimetry - A New Tool for Assessing Retinal Sensitivity in Macular Diseases.Journal of clinical and diagnostic research : JCDR · 2017Article
- Fixation Stability Measurement Using Two Types of Microperimetry Devices.Translational vision science & technology · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo compare the retinal sensitivity measurements obtained with two microperimeters, the Micro-Perimeter 1 (MP-1) and the Optos optical coherence tomography (OCT)/scanning laser ophthalmoscope (SLO) in subjects with and without maculopathies.
methodsForty-five eyes with no known ocular disease and 47 eyes with maculopathies were examined using both microperimeters. A contrast-adjusted scale was applied to resolve the different stimuli and background luminance existing between the two devices.
resultsThere was a strong ceiling effect with the MP-1 in the healthy group, with 90.1% (1136 of 1260) test points clustered at 20 dB. The mean sensitivity for the corresponding points in the OCT/SLO was 25.8 ± 1.9 dB. A floor effect was also observed with the OCT/SLO in the maculopathy group with 9.7% (128 of 1316) points clustered at 9-dB values. The corresponding mean sensitivity in the MP-1 was 1.7 ± 3.9 dB. A regression equation between the two microperimeters was established in the common 10 to19 dB intervals as: OCT/SLO = 15.6 + 0.564 × MP-1 - 0.009 × MP-1
conclusionThe OCT/SLO and the MP-1 provide two different ranges of contrasts for microperimetry examination. Broadening the dynamic range may minimize the constraint of the ceiling and floor effect. There is a significant mathematical relationship in the common interval of the contrast scale. TRANSLATIONAL RELEVANCE: Applying a unified and broadened dynamic range in different types of microperimeters will help to generate consistent clinical reference for measurements.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.