ArticleThe Journal of neuroscience nursing : journal of the American Association of Neuroscience Nurses2015
A patient care program for adjusting the autoinjector needle depth according to subcutaneous tissue thickness in patients with multiple sclerosis receiving subcutaneous injections of glatiramer acetate.
Article in The Journal of neuroscience nursing : journal of the American Association of Neuroscience Nurses, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 1 synthesis or guideline pooled it, 6 citations in OpenAlex.
- Analyzing the impact of subcutaneous injection needle, device, and administration characteristics on patient pain, anxiety, and safety: a systematic literature review.Drug delivery · 2026Pooled it
- Biocompatible near-infrared quantum dots delivered to the skin by microneedle patches record vaccination.Science translational medicine · 2019Article
- Evaluation of performance, acceptance, and compliance of an auto-injector in healthy and rheumatoid arthritic subjects measured by a motion capture system.Patient preference and adherence · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe perceived pain on injection site caused by subcutaneous (SC) self-injection may negatively affect acceptance and adherence to treatment in patients with multiple sclerosis (MS). Pain on injection may be caused by inaccurate injection technique, inadequate needle length adjustment, or repeated use of the same injection body area. However, information is lacking concerning the optimal needle depth to minimize the injection pain.
objectiveThe purpose of this program was to characterize the perceived injection-site pain associated with the use of various injection depths of the autoinjector of glatiramer acetate (GA) based on SC tissue thickness (SCT) of the injection site.
methodsThis was a pilot program performed by MS-specialized nurses in patients with MS new to GA. Patients were trained by MS nurses on the preparation and administration of SC injection and on an eight-site rotation (left and right arms, thighs, abdomen, and upper quadrant of the buttock). The needle length setting was selected based on SCT measures as follows: 4 or 6 mm for SCT < 25 mm, 6 or 8 mm for SCT between 25 and 50 mm, and 8 or 10 mm for SCT > 50 mm. Injection pain was rated using a visual analog scale (VAS) at 5- and 40-minute postinjection and during two 24-day treatment periods.
resultsThirty-eight patients with MS were evaluated. The mean SCT ranged from 15.5 mm in the upper outer quadrant of the buttocks to 29.2 mm in the thighs. The mean perceived pain on injection was below 3 for all the injection sites, at both time points (5 and 40 minutes) and during both 24-day evaluation periods. The mean VAS scores were significantly greater after 5 minutes of injection compared with that reported 40-minute postinjection during both 24-day treatment periods and for all the injection areas. Mean VAS measures at 5- and 40-minute postinjection significantly decreased during the second 24-day treatment period with respect to that reported during the first 24 SC injections for all injection sites.
conclusionsOur findings suggest that the adjustment of injection depth of SC GA autoinjector according to SCT of body injection areas is suitable to maintain a low degree of postinjection pain. Moreover, our results also may indicate that the use of needle lengths of 6 mm or shorter is appropriate with regard to injection pain for adult patients with MS with SCT < 50 mm.