Evidence map›Paper›PMID 25222483›Full record

ArticlePloS one2014

New developed cylindrical TM010 mode EPR cavity for X-band in vivo tooth dosimetry.

Guo Junwang, Yuan Qingquan, Cong Jianbo, Ma Lei, Dong Guofu, Yang Guoshan, Wu Ke

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.9field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 15 citations in OpenAlex.

  1. Rapid scan EPR: Automated digital resonator control for low-latency data acquisition.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2022
    Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Guo JunwangBeijing Institute of Radiation Medicine, Beijing, China.
Yuan QingquanBeijing Institute of Radiation Medicine, Beijing, China.
Cong JianboBeijing Institute of Radiation Medicine, Beijing, China.
Ma LeiBeijing Institute of Radiation Medicine, Beijing, China.
Dong GuofuBeijing Institute of Radiation Medicine, Beijing, China.
Yang GuoshanBeijing Institute of Radiation Medicine, Beijing, China.
Wu KeBeijing Institute of Radiation Medicine, Beijing, China.
Beijing Radiation Center · CN

Funding

Scientific and Administrative Core: Dartmouth Medical SchoolU19AI091173 · NIAID · DARTMOUTH COLLEGE · PI SWARTS, STEVEN GREGORY · 2010 to 2014
$16.3M
NIAID NIH HHS U19 AI091173NIAID NIH HHS U19-AI091173-04
6 · The paper itself

Abstract

EPR tooth in vivo dosimetry is an attractive approach for initial triage after unexpected nuclear events. An X-band cylindrical TM010 mode resonant cavity was developed for in vivo tooth dosimetry and used in EPR applications for the first time. The cavity had a trapezoidal measuring aperture at the exact position of the cavity's cylindrical wall where strong microwave magnetic field H1 concentrated and weak microwave electric field E1 distributed. Theoretical calculations and simulations were used to design and optimize the cavity parameters. The cavity features were evaluated by measuring DPPH sample, intact incisor samples embed in a gum model and the rhesus monkey teeth. The results showed that the cavity worked at designed frequency and had the ability to make EPR spectroscopy in relative high sensitivity. Sufficient modulation amplitude and microwave power could be applied into the aperture. Radiation induced EPR signal could be observed remarkably from 1 Gy irradiated intact incisor within only 30 seconds, which was among the best in scan time and detection limit. The in vivo spectroscopy was also realized by acquiring the radiation induced EPR signal from teeth of rhesus monkey whose teeth was irradiated by dose of 2 Gy. The results suggested that the cavity was sensitive to meet the demand to assess doses of significant level in short time. This cavity provided a very potential option for the development of X-band in vivo dosimetry.

Indexed as

AnimalsBody BurdenMacaca mulattaRadioactive Hazard ReleaseRadiometrySensitivity and SpecificitySignal-To-Noise RatioToothTriage

Identifiers

PMID25222483
PMCPMC4164439
OpenAlexW2054026072

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.