Evidence map›Paper›PMID 25217037›Full record

ArticleHeart and vessels2016

A preliminary feasibility study of simultaneous dual-isotope imaging with a solid-state dedicated cardiac camera for evaluating myocardial perfusion and fatty acid metabolism.

Toshiyuki Ko, Yuko Utanohara, Yasuhiro Suzuki, Makiko Kurihara, Nobuo Iguchi, Jun Umemura, Tetsuya Sumiyoshi, Hitonobu Tomoike

Abstract read
PubMed Publisher
In one paragraph

Article in Heart and vessels, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
3.0field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 20 citations in OpenAlex.

  1. Review
  2. Nuclear medicine and molecular imaging · 2024
    Review
  3. Feasibility of simultaneousJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021
    Observational
  4. Roadmap on nanomedicine.Nanotechnology · 2021
    Article
  5. Article
  6. Creation and characterization of normal myocardial perfusion imaging databases using the IQ·SPECT system.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2018
    Article
  7. Article
  8. Article
  9. Novel SPECT Technologies and Approaches in Cardiac Imaging.Cardiovascular innovations and applications · 2016
    Article
  10. Article
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Toshiyuki KoDepartment of Cardiology, Sakakibara Heart Institute, 3-16-1 Asahi-Cho, Fuchu, Tokyo, 183-0003, Japan.
Yuko UtanoharaDepartment of Cardiology, Sakakibara Heart Institute, 3-16-1 Asahi-Cho, Fuchu, Tokyo, 183-0003, Japan.
Yasuhiro SuzukiDepartment of Cardiology, Sakakibara Heart Institute, 3-16-1 Asahi-Cho, Fuchu, Tokyo, 183-0003, Japan.
Makiko KuriharaDepartment of Cardiology, Sakakibara Heart Institute, 3-16-1 Asahi-Cho, Fuchu, Tokyo, 183-0003, Japan.
Nobuo IguchiDepartment of Cardiology, Sakakibara Heart Institute, 3-16-1 Asahi-Cho, Fuchu, Tokyo, 183-0003, Japan. niguchi@shi.heart.or.jp.
Jun UmemuraDepartment of Cardiology, Sakakibara Heart Institute, 3-16-1 Asahi-Cho, Fuchu, Tokyo, 183-0003, Japan.
Tetsuya SumiyoshiDepartment of Cardiology, Sakakibara Heart Institute, 3-16-1 Asahi-Cho, Fuchu, Tokyo, 183-0003, Japan.
Hitonobu TomoikeDepartment of Cardiology, Sakakibara Heart Institute, 3-16-1 Asahi-Cho, Fuchu, Tokyo, 183-0003, Japan.
Sakakibara Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Simultaneous dual-isotope SPECT imaging with 201Tl and (123)I-β-methyl-p-iodophenylpentadecanoic acid (BMIPP) is used to study the perfusion-metabolism mismatch. It predicts post-ischemic functional recovery by detecting stunned myocardium. On the other hand, (99m)Tc-MIBI is another radioisotope widely used in myocardial perfusion imaging because of its better image quality and lower radiation exposure than 201Tl. However, since the photopeak energies of (99m)Tc and (123)I are very similar, crosstalk hampers the simultaneous use of these two radioisotopes. To overcome this problem, we conducted simultaneous dual-isotope imaging study using the D-SPECT scanner (Spectrum-Dynamics, Israel) which has a novel detector design and excellent energy resolution. We first conducted a basic experiment using cardiac phantom to simulate the condition of normal perfusion and impaired fatty acid metabolism. Subsequently, we prospectively recruited 30 consecutive patients who underwent successful percutaneous coronary intervention for acute myocardial infarction, and performed (99m)Tc-MIBI/(123)I-BMIPP dual-isotope imaging within 5 days after reperfusion. Images were interpreted by two experienced cardiovascular radiologists to identify the infarcted and stunned areas based on the coronary artery territories. As a result, cardiac phantom experiment revealed no significant crosstalk between (99m)Tc and (123)I. In the subsequent clinical study, (99m)Tc-MIBI/(123)I-BMIPP dual-isotope imaging in all participant yielded excellent image quality and detected infarcted and stunned areas correctly when compared with coronary angiographic findings. Furthermore, we were able to reduce radiation exposure to significantly approximately one-eighth. In conclusion, we successfully demonstrated the practical application of simultaneous assessment of myocardial perfusion and fatty acid metabolism by (99m)Tc-MIBI and (123)I-BMIPP using a D-SPECT cardiac scanner. Compared with conventional (201)TlCl/(123)I-BMIPP dual-isotope imaging, the use of (99m)Tc-MIBI instead of (201)TlCl improves image quality as well as lowers radiation exposure.

Indexed as

Tomography, Emission-Computed, Single-PhotonAdultAgedAged, 80 and overCoronary AngiographyFatty AcidsFeasibility StudiesFemaleHeartHumansIofetamineJapanMaleMiddle AgedMyocardial InfarctionMyocardial Perfusion ImagingFatty AcidsIofetamineRadiopharmaceuticalsTechnetium Tc 99m Sestamibi99mTc-MIBIBMIPPCZT cameraPerfusion–metabolism mismatchSimultaneous dual-isotope imaging

Identifiers

PMID25217037
OpenAlexW2133517594

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.