Evidence map›Paper›PMID 25212069›Full record

ArticleBiosensors & bioelectronics2015

Cell streak imaging cytometry for rare cell detection.

Joshua Balsam, Hugh Alan Bruck, Avraham Rasooly

Abstract read
In one paragraph

Article in Biosensors & bioelectronics, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.0field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Review
  3. Engineering opportunities in cancer immunotherapy.Proceedings of the National Academy of Sciences of the United States of America · 2015
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Joshua BalsamDivision of Biology, Office of Science and Engineering, FDA, Silver Spring, MD 20993, United States; University of Maryland, College Park, MD 20742, United States.
Hugh Alan BruckUniversity of Maryland, College Park, MD 20742, United States.
Avraham RasoolyDivision of Biology, Office of Science and Engineering, FDA, Silver Spring, MD 20993, United States; Office of Cancer Complementary and Alternative Medicine, National Cancer Institute, Rockville, MD 20850, United States. Electronic address: rasoolya@mail.nih.gov.
Office of Science · USUniversity of Maryland, College Park · US

Funding

Intramural NIH HHS Z99 CA999999
6 · The paper itself

Abstract

Detection of rare cells, such as circulating tumor cells, have many clinical applications. To measure rare cells with increased sensitivity and improved data managements, we developed an imaging flow cytometer with a streak imaging mode capability. The new streak mode imaging mode utilizes low speed video to capture moving fluorescently labeled cells in a flow cell. Each moving cell is imaged on multiple pixels on each frame, where the cell path is marked as a streak line proportional to the length of the exposure. Finding rare cells (e.g., <1 cell/mL) requires measuring larger sample volumes to achieve higher sensitivity, therefore we combined streak mode imaging with a "wide" high throughput flow cell (e.g. flow rates set to 10 mL/min) in contrast to the conventional "narrow" hydrodynamic focusing cells typically used in cytometry that are inherently limited to low flow rates. The new flow cell is capable of analyzing 20 mL/min of fluorescently labeled cells. To further increase sensitivity, the signal to noise ratio of the images was also enhanced by combining three imaging methods: (1) background subtraction, (2) pixel binning, and (3) CMOS color channel selection. The streaking mode cytometer has been used for the analysis of SYTO-9 labeled THP-1 human monocytes in buffer and in blood. Samples of cells at 1 cell/mL and 0.1 cell/mL were analyzed in 30 mL with flow rates set to 10 mL/min and frame rates of 4 fps (frame per second). For the target of 1 cell/mL, an average concentration of 0.91 cell/mL was measured by cytometry, with a standard error of 0.03 (C(95) = 0.85-0.97). For the target of 0.1 cell/mL, an average concentration of 0.083 cell/mL was measured, with a standard error of 0.01 (C(95) = 0.065-0.102). Whole blood was also spiked with SYTO-9 labeled cells to a concentration of 10 cell/mL, and the average flow cytometry measurement was 8.7 cells/mL (i.e. 0.87 cells/mL in diluted blood) with a 95% CL of 8.1-9.2 cells/mL. This demonstrated the ability to detect rare cells in blood with high accuracy. Such detection approaches for rare cells have many potential clinical applications. Furthermore, the simplicity and low cost of this device may enable expansion of cell-based clinical diagnostics, especially in resource-poor settings.

Indexed as

Cell SeparationCell TrackingEquipment DesignEquipment Failure AnalysisFlow CytometryImage Interpretation, Computer-AssistedMicrofluidic Analytical TechniquesMicroscopy, ConfocalPattern Recognition, AutomatedFlow cytometryImage enhancementmHealthRare cellsResource-poor settingsWide-field imaging