ReviewStrahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al]2014
Novel radiotherapy techniques for involved-field and involved-node treatment of mediastinal Hodgkin lymphoma: when should they be considered and which questions remain open?
Review in Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al], 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Quality control of involved field radiotherapy in the HD 13 and HD 14 trials : Report of the radiotherapy panel of the German Hodgkin Study Group (GHSG).Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2017Trial
- Intensity modulated proton therapy compared to volumetric modulated arc therapy in the irradiation of young female patients with hodgkin's lymphoma. Assessment of risk of toxicity and secondary cancer induction.Radiation oncology (London, England) · 2020Article
- Heart-sparing volumetric modulated arc therapy for whole lung irradiation.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2019Article
- Proton versus photon deep inspiration breath hold technique in patients with hodgkin lymphoma and mediastinal radiation : A PLANNING COMPARISON OF DEEP INSPIRATION BREATH HOLD INTENSITY MODULATION RADIOTHERAPY AND INTENSITY MODULATED PROTON THERAPY.Radiation oncology (London, England) · 2018Article
- Patterns of failure of diffuse large B‑cell lymphoma patients after involved-site radiotherapy.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2017Article
- Flat detector cone-beam CT-guided percutaneous needle biopsy of mediastinal lesions: preliminary experience.La Radiologia medica · 2016Article
- Radiation-induced camptocormia and dropped head syndrome: Review and case report of radiation-induced movement disorders.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2015Review
- The concept and evolution of involved site radiation therapy for lymphoma.International journal of clinical oncology · 2015Review
- Breath-hold technique in conventional APPA or intensity-modulated radiotherapy for Hodgkin's lymphoma: Comparison of ILROG IS-RT and the GHSG IF-RT.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2015Article
- The impact of protocol assignment for older adolescents with hodgkin lymphoma.Frontiers in oncology · 2014Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeHodgkin lymphoma (HL) is a highly curable disease. Reducing late complications and second malignancies has become increasingly important. Radiotherapy target paradigms are currently changing and radiotherapy techniques are evolving rapidly.
designThis overview reports to what extent target volume reduction in involved-node (IN) and advanced radiotherapy techniques, such as intensity-modulated radiotherapy (IMRT) and proton therapy-compared with involved-field (IF) and 3D radiotherapy (3D-RT)- can reduce high doses to organs at risk (OAR) and examines the issues that still remain open.
resultsAlthough no comparison of all available techniques on identical patient datasets exists, clear patterns emerge. Advanced dose-calculation algorithms (e.g., convolution-superposition/Monte Carlo) should be used in mediastinal HL. INRT consistently reduces treated volumes when compared with IFRT with the exact amount depending on the INRT definition. The number of patients that might significantly benefit from highly conformal techniques such as IMRT over 3D-RT regarding high-dose exposure to organs at risk (OAR) is smaller with INRT. The impact of larger volumes treated with low doses in advanced techniques is unclear. The type of IMRT used (static/rotational) is of minor importance. All advanced photon techniques result in similar potential benefits and disadvantages, therefore only the degree-of-modulation should be chosen based on individual treatment goals. Treatment in deep inspiration breath hold is being evaluated. Protons theoretically provide both excellent high-dose conformality and reduced integral dose.
conclusionFurther reduction of treated volumes most effectively reduces OAR dose, most likely without disadvantages if the excellent control rates achieved currently are maintained. For both IFRT and INRT, the benefits of advanced radiotherapy techniques depend on the individual patient/target geometry. Their use should therefore be decided case by case with comparative treatment planning.
Indexed as
Identifiers
25209551What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.