SynthesisThe Cochrane database of systematic reviews2014
Intermittent catheterisation for long-term bladder management.
Synthesis in The Cochrane database of systematic reviews, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It has been retracted, and should not be counted. It is linked to 3 registered trials, which are not on this map. Cited by 25 papers, 5 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Use of Autologous Adipose-Derived Stem/Stromal Cells In Symptomatic Benign Prostate Hypertrophy
Randomized Clinical Trial Using Sterile Single-use and Reused Polyvinylchloride Catheter For Intermittent Catheterization With Clean Technique In Neurogenic Bladder Due to Spina Bifida
Effectiveness and Acceptability of Two Insertable Device Models for Non-surgical Management of Obstetric Fistula: a Randomized Crossover Trial
Who cites it
25 citing papers in PubMed, 5 syntheses or guidelines pooled it, 80 citations in OpenAlex.
- Intermittent catheter techniques, strategies and designs for managing long-term bladder conditions.The Cochrane database of systematic reviews · 2021Pooled it
- Catheters for intermittent catheterization: a systematic review and network meta-analysis.Spinal cord · 2021Pooled it
- Intermittent Catheters for Chronic Urinary Retention: A Health Technology Assessment.Ontario health technology assessment series · 2019Pooled it
- WITHDRAWN: Intermittent catheterisation for long-term bladder management.The Cochrane database of systematic reviews · 2017Pooled it
- Intermittent catheterisation with hydrophilic and non-hydrophilic urinary catheters: systematic literature review and meta-analyses.BMC urology · 2017Pooled it
- Optimizing Intermittent Catheterization Following Spinal Cord Injury: A Narrative Review Using the WHO Health System Building Blocks Framework.Advances in urology · 2026Review
- The temporal burden of preparing catheters for re-use in adults with spinal cord injury: a cross-sectional study.Spinal cord series and cases · 2023Article
- Effects of central-peripheral FMS on urinary retention after spinal cord injury: a pilot randomized controlled trial protocol.Frontiers in neurology · 2023Article
- Article
- Survey on Untethering of the Spinal Cord and Urological Manifestations among Spina Bifida Patients in Malaysia.Children (Basel, Switzerland) · 2022Article
- Multidrug-resistant Uro-associatedEuropean urology open science · 2022Article
- Variables associated with an inability to learn clean intermittent self-catheterization after urogynecologic surgery.International urogynecology journal · 2020Article
- Effects of clean intermittent self-catheterization on late bladder dysfunction after radical hysterectomy in cervical cancer.The Journal of international medical research · 2020Article
- Clean intermittent catheterization: Single use vs. reuse.Canadian Urological Association journal = Journal de l'Association des urologues du Canada · 2019Review
- Adult Neurogenic Lower Urinary Tract Dysfunction and Intermittent Catheterisation in a Community Setting: Risk Factors Model for Urinary Tract Infections.Advances in urology · 2019Review
- User perception of a new hydrophilic-coated male urinary catheter for intermittent use.Nursing open · 2019Article
- Intermittent Catheterization: The Devil Is in the Details.Journal of neurotrauma · 2018Article
- Disease-Specific Outcomes of Botulinum Toxin Injections for Neurogenic Detrusor Overactivity.The Urologic clinics of North America · 2017Review
- Review
- Clean intermittent catheterization revisited.International urology and nephrology · 2016Review
Corrections and comments
- Retraction · 2017-08-08Investigation by Journal/Publisher · Unreliable Data · Unreliable Results and/or Conclusions ·
- Updated by
- Update of
Authors and funding
4 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundIntermittent catheterisation is a commonly recommended procedure for people with incomplete bladder emptying. There are now several designs of intermittent catheter (e.g. different lengths, 'ready to use' presentation) with different materials (e.g. PVC-free) and coatings (e.g. hydrophilic). The most frequent complication of intermittent catheterisation is urinary tract infection (UTI), but satisfaction, preference and ease of use are also important to users. It is unclear which catheter designs, techniques or strategies affect the incidence of UTI, which are preferable to users and which are most cost effective.
objectivesTo compare one type of catheter design versus another, one type of catheter material versus another, aseptic catheterisation technique versus clean technique, single-use (sterile) catheters versus multiple-use (clean) catheters, self-catheterisation versus catheterisation by others and any other strategies designed to reduce UTI and other complications or improve user-reported outcomes (user satisfaction, preference, ease of use) and cost effectiveness in adults and children using intermittent catheterisation for incomplete bladder emptying. SEARCH
methodsWe searched the Cochrane Incontinence Group Specialised Register, which contains trials identified from the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, MEDLINE in process, and handsearching of journals and conference proceedings (searched 30 September 2013), the reference lists of relevant articles and conference proceedings, and we attempted to contact other investigators for unpublished data or for clarification. SELECTION CRITERIA: Randomised controlled trials (RCTs) or randomised cross-over trials comparing at least two different catheter designs, catheterisation techniques or strategies. DATA COLLECTION AND ANALYSIS: Two review authors assessed the methodological quality of trials and abstracted data. For dichotomous variables, risk ratios and 95% confidence intervals were derived for each outcome where possible. For continuous variables, mean differences and 95% confidence intervals were calculated for each outcome. Because of trial heterogeneity, it was not always possible to combine data to give an overall estimate of treatment effect. MAIN
resultsThirty-one trials met the inclusion criteria, including 13 RCTs and 18 cross-over trials. Most were small (less than 60 participants completed), although five trials had more than 100 participants. There was considerable variation in length of follow-up and definitions of UTI. Participant dropout was a problem for several trials, particularly where there was long-term follow-up to measure incidence of UTI. Fifteen trials were more than 10 years old and focused mainly on comparing different catheterisation techniques (e.g. single versus multiple-use) on clinical outcomes whereas, several more recent trials have focused on comparing different types of catheter designs or materials, especially coatings, and user preference. It was not possible to combine data from some trials owing to variations in the catheters tested and in particular the catheter coatings. Where there were data, confidence intervals around estimates were wide and hence clinically important differences in UTI and other outcomes could neither be identified nor reliably ruled out. No study assessed cost-effectiveness. AUTHORS'
conclusionsDespite a total of 31 trials, there is still no convincing evidence that the incidence of UTI is affected by use of aseptic or clean technique, coated or uncoated catheters, single (sterile) or multiple-use (clean) catheters, self-catheterisation or catheterisation by others, or by any other strategy. Results from user-reported outcomes varied. The current research evidence is weak and design issues are significant. More well-designed trials are strongly recommended. Such trials should include analysis of cost-effectiveness because there are likely to be substantial differences associated with the use of different catheter designs, catheterisation techniques and strategies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.