Evidence map›Paper›PMID 25203308›Full record

SynthesisThe Cochrane database of systematic reviews2014

Automated weaning and SBT systems versus non-automated weaning strategies for weaning time in invasively ventilated critically ill adults.

Karen E A Burns, Francois Lellouche, Rosane Nisenbaum, Martin R Lessard, Jan O Friedrich

Open access · bronzeAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers, 5 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed, 5 pooled it
5.3field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 5 syntheses or guidelines pooled it, 56 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Pooled it
  5. Pooled it
  6. Trial
  7. Trial
  8. Article
  9. Review
  10. Perceived responsibility for mechanical ventilation and weaning decisions in intensive care units in the Kingdom of Saudi Arabia.Canadian journal of respiratory therapy : CJRT = Revue canadienne de la therapie respiratoire : RCTR · 2023
    Article
  11. Article
  12. Review
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Karen E A BurnsInterdepartmental Division of Critical Care, Keenan Research Centre/Li Ka Shing Knowledge Institute, University of Toronto, 30 Bond Street, Rm 4-045 Queen Wing, Toronto, ON, Canada, M5B 1WB.
Francois Lellouche
Rosane Nisenbaum
Martin R Lessard
Jan O Friedrich
Université Laval · CAUniversity of Toronto · CASt. Michael's Hospital · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAutomated systems use closed-loop control to enable ventilators to perform basic and advanced functions while supporting respiration. SmartCare™ is a unique automated weaning system that measures selected respiratory variables, adapts ventilator output to individual patient needs by operationalizing predetermined algorithms and automatically conducts spontaneous breathing trials (SBTs) when predetermined thresholds are met.

objectivesThe primary objective of this review was to compare weaning time (time from randomization to extubation as defined by study authors) between invasively ventilated critically ill adults weaned by automated weaning and SBT systems versus non-automated weaning strategies.As secondary objectives, we ascertained differences between effects of alternative weaning strategies on clinical outcomes (time to successful extubation, time to first SBT and first successful SBT, mortality, ventilator-associated pneumonia, total duration of ventilation, lengths of intensive care unit (ICU) and hospital stay, use of non-invasive ventilation (NIV), adverse events and clinician acceptance).The third objective of our review was to use subgroup analyses to explore variations in weaning time, length of ICU stay, mortality, ventilator-associated pneumonia, use of NIV and reintubation according to (1) the type of clinician primarily involved in implementing the automated weaning and SBT strategy, (2) the ICU (as a reflection of the population involved) and (3) the non-automated (control) weaning strategy utilized.We conducted a sensitivity analysis to evaluate variations in weaning time based on (4) the methodological quality (low or unclear versus high risk of bias) of the included studies. SEARCH

methodsWe searched the Cochrane Central Register of Controlled Trials (CENTRAL) 2013, Issue 5; MEDLINE (1966 to 31 May 2013); EMBASE (1988 to 31 May 2013); the Cumulative Index to Nursing and Allied Health Literature (CINAHL) (1982 to 31 May 2013), Evidence-Based Medicine Reviews and Ovid HealthSTAR (1999 to 31 May 2013), as well as conference proceedings and trial registration websites; we also contacted study authors and content experts to identify potentially eligible trials. SELECTION CRITERIA: Randomized and quasi-randomized trials comparing automated weaning and SBT systems versus non-automated weaning strategies in intubated adults. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed trial quality and abstracted data according to prespecified criteria. Sensitivity and subgroup analyses were planned to assess the impact on selected outcomes of the following: (1) the type of clinician primarily involved in implementing automated weaning and SBT systems, (2) the ICU (as a reflection of the population involved) and (3) the non-automated (control) weaning strategy utilized. MAIN

resultsWe pooled summary estimates from 10 trials evaluating SmartCare™ involving 654 participants. Overall, eight trials were judged to be at low or unclear risk of bias, and two trials were judged to be at high risk of bias. Compared with non-automated strategies, SmartCare™ decreased weaning time (mean difference (MD) -2.68 days, 95% confidence interval (CI) -3.99 to -1.37; P value < 0.0001, seven trials, 495 participants, moderate-quality evidence), time to successful extubation (MD -0.99 days, 95% CI -1.89 to -0.09; P value 0.03, seven trials, 516 participants, low-quality evidence), length of ICU stay (MD -5.70 days, 95% CI -10.54 to -0.85; P value 0.02, six trials, 499 participants, moderate-quality evidence) and proportions of participants receiving ventilation for longer than seven and 21 days (risk ratio (RR) 0.44, 95% CI 0.23 to 0.85; P value 0.01 and RR 0.39, 95% CI 0.18 to 0.86; P value 0.02). SmartCare™ reduced the total duration of ventilation (MD -1.68 days, 95% CI -3.33 to -0.03; P value 0.05, seven trials, 521 participants, low-quality evidence) and the number of participants receiving ventilation for longer than 14 days (RR 0.61, 95% CI 0.37 to 1.00; P value 0.05); however the estimated effects were imprecise. SmartCare™ had no effect on time to first successful SBT, mortality or adverse events, specifically reintubation. Subgroup analysis suggested that trials with protocolized (versus non-protocolized) control weaning strategies reported significantly shorter ICU stays. Sensitivity analysis excluded two trials with high risk of bias and supported a trend toward significant reductions in weaning time favouring SmartCare™. AUTHORS'

conclusionsCompared with non-automated weaning strategies, weaning with SmartCare™ significantly decreased weaning time, time to successful extubation, ICU stay and proportions of patients receiving ventilation for longer than seven days and 21 days. It also showed a favourable trend toward fewer patients receiving ventilation for longer than 14 days; however the estimated effect was imprecise. Summary estimates from our review suggest that these benefits may be achieved without increasing the risk of adverse events, especially reintubation; however, the quality of the evidence ranged from low to moderate, and evidence was derived from 10 small randomized controlled trials.

Indexed as

Critical IllnessVentilators, MechanicalAdultAutomationHumansIntensive Care UnitsLength of StayRandomized Controlled Trials as TopicTime FactorsVentilator WeaningWork of Breathing

Identifiers

PMID25203308
PMCPMC6516852
OpenAlexW2127965817

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.