Comparison of optimal performance at 300keV of three direct electron detectors for use in low dose electron microscopy.

G McMullan, A R Faruqi, D Clare, R Henderson

Abstract read
In one paragraph

Article in Ultramicroscopy, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 112 papers.

0numbers the graph read from it
0cells of the map it votes in
112citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

112 citing papers in PubMed.

  1. Review
  2. LowDoseWizard: rapid and standardized setup of low-dose cryo-TEM imaging in SerialEM.Acta crystallographica. Section D, Structural biology · 2026
    Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Extending the reach of single-particle cryoEM.Current opinion in structural biology · 2025
    Review
  8. Review
  9. In-cell chromatin structure by Cryo-FIB and Cryo-ET.Current opinion in structural biology · 2025
    Review
  10. Review
  11. Fast event-based electron counting for small-molecule structure determination by MicroED.Acta crystallographica. Section C, Structural chemistry · 2025
    Article
  12. Article
  13. Article
  14. Review
  15. Cryo-electron microscopy-based drug design.Frontiers in molecular biosciences · 2024
    Review
  16. Structural Analysis of Protein Complexes by Cryo-Electron Microscopy.Methods in molecular biology (Clifton, N.J.) · 2024
    Review
  17. Structure determination by cryoEM at 100 keV.Proceedings of the National Academy of Sciences of the United States of America · 2023
    Article
  18. Charting the molecular landscape of the cell.Structure (London, England : 1993) · 2023
    Review
  19. Article
  20. Review

52 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

G McMullanMRC Laboratory of Molecular Biology, Francis Crick Avenue, Cambridge CB2 0QH, United Kingdom. Electronic address: gm2@mrc-lmb.cam.ac.uk.
A R FaruqiMRC Laboratory of Molecular Biology, Francis Crick Avenue, Cambridge CB2 0QH, United Kingdom.
D ClareCrystallography and Institute of Structural and Molecular Biology, Birkbeck College, University of London, Malet Street, London WC1E 7HX, United Kingdom.
R HendersonMRC Laboratory of Molecular Biology, Francis Crick Avenue, Cambridge CB2 0QH, United Kingdom.

Funding

Medical Research Council MC_U105184321Medical Research Council MC_U105184322Medical Research Council U105184322Wellcome TrustWellcome Trust 089050Wellcome Trust 101488
6 · The paper itself

Abstract

Low dose electron imaging applications such as electron cryo-microscopy are now benefitting from the improved performance and flexibility of recently introduced electron imaging detectors in which electrons are directly incident on backthinned CMOS sensors. There are currently three commercially available detectors of this type: the Direct Electron DE-20, the FEI Falcon II and the Gatan K2 Summit. These have different characteristics and so it is important to compare their imaging properties carefully with a view to optimise how each is used. Results at 300keV for both the modulation transfer function (MTF) and the detective quantum efficiency (DQE) are presented. Of these, the DQE is the most important in the study of radiation sensitive samples where detector performance is crucial. We find that all three detectors have a better DQE than film. The K2 Summit has the best DQE at low spatial frequencies but with increasing spatial frequency its DQE falls below that of the Falcon II.