Evidence map›Paper›PMID 25192788›Full record

ArticleAnalytical and bioanalytical chemistry2014

Microscale depletion of high abundance proteins in human biofluids using IgY14 immunoaffinity resin: analysis of human plasma and cerebrospinal fluid.

Seok-Won Hyung, Paul D Piehowski, Ronald J Moore, Daniel J Orton, Athena A Schepmoes, Therese R Clauss, Rosalie K Chu, Thomas L Fillmore, Heather Brewer, Tao Liu and 2 more

Abstract read
In one paragraph

Article in Analytical and bioanalytical chemistry, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Contributions of immunoaffinity chromatography to deep proteome profiling of human biofluids.Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2016
    Review
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Seok-Won HyungBiological Sciences Division and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, WA, 99352, USA, swhyung@kriss.re.kr.
Paul D Piehowski
Ronald J Moore
Daniel J Orton
Athena A Schepmoes
Therese R Clauss
Rosalie K Chu
Thomas L Fillmore
Heather Brewer
Tao Liu
Rui Zhao
Richard D Smith

Funding

WORKSHOP AND TRAINING ACTIVITIESP41RR018522 · NCRR · BATTELLE PACIFIC NORTHWEST LABORATORIES · PI BELOV, MIKHAIL · 2003 to 2011
$25.1M
Equipment Supplement Request for a Research Resource for Ultra-sensitive High Throughput ProteomicsP41GM103493 · NIGMS · BATTELLE PACIFIC NORTHWEST LABORATORIES · PI SMITH, RICHARD D · 2012 to 2022
$22.6M
NCRR NIH HHS 5 P41 RR018522-10NCRR NIH HHS P41 RR018522NIGMS NIH HHS 8 P41 GM103493-10NIGMS NIH HHS P41 GM103493
6 · The paper itself

Abstract

Removal of highly abundant proteins in plasma is often carried out using immunoaffinity depletion to extend the dynamic range of measurements to lower abundance species. While commercial depletion columns are available for this purpose, they generally are not applicable to limited sample quantities (<20 μL) due to low yields stemming from losses caused by nonspecific binding to the column matrix and concentration of large eluent volumes. Additionally, the cost of the depletion media can be prohibitive for larger-scale studies. Modern LC-MS instrumentation provides the sensitivity necessary to scale-down depletion methods with minimal sacrifice to proteome coverage, which makes smaller volume depletion columns desirable for maximizing sample recovery when samples are limited, as well as for reducing the expense of large-scale studies. We characterized the performance of a 346 μL column volume microscale depletion system, using four different flow rates to determine the most effective depletion conditions for ∼6-μL injections of human plasma proteins and then evaluated depletion reproducibility at the optimum flow rate condition. Depletion of plasma using a commercial 10-mL depletion column served as the control. Results showed depletion efficiency of the microscale column increased as flow rate decreased, and that our microdepletion was reproducible. In an initial application, a 600-μL sample of human cerebrospinal fluid (CSF) pooled from multiple sclerosis patients was depleted and then analyzed using reversed phase liquid chromatography-mass spectrometry to demonstrate the utility of the system for this important biofluid where sample quantities are more commonly limited.

Indexed as

AlbuminsBiomarkersBlood ProteinsChromatography, AffinityChromatography, LiquidHumansMultiple SclerosisProteomeProteomicsTandem Mass SpectrometryAlbuminsBiomarkersBlood ProteinsProteome

Identifiers

PMID25192788
PMCPMC4208972

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.