ArticleTanaffos2011
Novel technique for placement of laryngeal mask airway in difficult pediatric airways.
Article in Tanaffos, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 0 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe main responsibility of an anesthesiologist is to safely maintain an open airway and preserve sufficient gas exchange in the lungs. This role becomes more significant when managing children especially those with difficult airways (DA). In such cases, a quick appropriate action can decrease the related mortality and morbidity. Laryngeal mask airway (LMA) is a device used in cases with difficult airways. Its placement is much more difficult in children especially those with DA. There is a greater risk of malpositioning and its insertion with routine techniques is sometimes impossible. In this article, we introduce a new method for replacement of LMA in difficult pediatric airways (DPA). MATERIALS AND
methodsIn this before and after, pre and post design clinical trial, we evaluated 30 children with congenital anomalies and difficult airways who were candidates for elective eye surgery (short term). A written consent was obtained from the parents or the legal guardians of those who met the inclusion criteria. Inhalation anesthesia was induced by sevoflurane. The patients had assisted spontaneous respiration. No muscle relaxant was administered. LMA was inserted using the classic method in the anesthesia depth of BIS = 35-40. After 2 unsuccessful attempts according to the criteria for adequate function of LMA, we tried placing the LMA using our innovated method after meeting the primary requirements and reaching the anesthesia depth of 35-40. In this method, the index finger of the left hand was placed on the tongue pushing it downwards (towards the floor of the mouth) when inserting the LMA. This way, we assisted LMA passing down the pharynx resulting in its adequate positioning. Criteria for adequate function of LMA in both classic and innovated insertion methods included monitoring of easy ventilation, no resistance during exhalation, adequate chest movement, no air leakage, optimal airway pressure, optimal lung compliance, level of oxygenation of arterial blood and level of CO2 at the end of exhalation. In case of presence of air leakage with bag pressure below 15 cm of water, lack of chest movement during inhalation, upper airway pressure over 20 cm of water, SPO2 lower than 90% and low compliance of the lung, LMA placement would be considered a failure. In such cases, LMA would be immediately extracted and the required depth of anesthesia would be reached using an oxygen mask and required inhalations. Complications occurring during the procedure and after LMA extraction would be recorded.
resultsOur understudy population included 30 children in the age range of 1.5 months to 10 yrs (11 girls and 19 boys) who had clear DA criteria due to syndromes and severe congenital anomalies and were candidates for elective eye surgery. Duration of the operation was 30 to 60 minutes. In all 30 cases, LMA placement with the classic method was not successful after 2 attempts by an expert. LMA was successfully inserted for all cases by the same person using the innovated method after meeting the required criteria (BIS = 35-40). All ventilation indices were met and the operation was performed successfully with no complication.
conclusionThere is always a risk of unsuccessful LMA placement in difficult pediatric airways using the classic method of insertion. The innovated method recommends pushing down the tongue by the index finger of the left hand. Considering the hypersensitivity of children to hypoxia and risk of unsuccessful LMA placement by the classic method, the innovated placement method is advised in children suffering from anomalies associated with macroglossia.
Indexed as
Identifiers
25191364PMC4153147W2181328049What OpenQuestion holds
Registered trials