ArticleNeurosurgery2014
Force characterization of intracranial endovascular embolization: coil type, microcatheter placement, and insertion rate.
Article in Neurosurgery, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Review
- Article
- Vessel Curvature and Microcatheter-Detachable Coil Compatibility in Arterial Coil Embolization.Cureus · 2025Article
- Efficacy of embolo/sclerotherapy in the treatment of high-output cardiac failure caused by peripheral arteriovenous malformations.Frontiers in cardiovascular medicine · 2025Article
- Difference of coil distribution made by finishing coils in large size aneurysm model with radiolucent coils.Nagoya journal of medical science · 2023Article
- A deep-learning system to help make the surgical planning of coil embolization for unruptured intracranial aneurysms.Chinese neurosurgical journal · 2023Article
- Initial Experience of Coil Embolization for Unruptured Intracranial Aneurysm Combined with Neuroform Atlas and Undersized Flexible Coils.Journal of neuroendovascular therapy · 2021Article
- Evaluation of Contact Force between Aneurysm Model and Coil for Embolization of Intracranial Aneurysms.Journal of neuroendovascular therapy · 2021Article
- Experimental study of coil delivery wire insertion force in intracranial aneurysm embolization: force discrepancy generated inside the microcatheter through that coil delivery wire passes.Nagoya journal of medical science · 2019Article
- Evaluation of the characteristics of various types of finishing coils for the embolization of intracranial aneurysms in an experimental model with radiolucent coils.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2017Article
- 3D Printing of Intracranial Aneurysms Using Fused Deposition Modeling Offers Highly Accurate Replications.AJNR. American journal of neuroradiology · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
backgroundIntraoperative rupture (IOR) is a rare, but potentially morbid complication of endovascular aneurysm coil embolization. Yet, IOR predictors have remained relatively uninvestigated in relation to coil design.
objectiveTo develop a novel in vitro aneurysm model to characterize forces exerted by coils of different design on the aneurysm during endovascular embolization that are hypothesized to contribute to IOR.
methodsA 3-mm saccular aneurysm model was developed with flat latex membrane at the dome apex. Membrane deflection was observed throughout simulated embolization and converted to force measurement. Simultaneous coil insertion and force measurement were accomplished with a compression strength-testing machine. Membrane and insertion forces across coil type, microcatheter tip placement, and insertion rate were evaluated.
resultsInsertion force and force directly on the aneurysm wall exhibited a difference, with framing coils exerting greatest force, followed by filling and finishing coils. Regarding microcatheter placement, a similar graded response in membrane and insertion forces was observed with positioning in the top-third of the aneurysm generating the greatest force compared with central and bottom-third placement. Insertion rate was also a factor with the slowest rate (10 mm/min) exhibiting the greatest membrane force, followed by lower forces at 30 and 50 mm/min. A multiple linear regression model was created to assess the contributions of each factor toward aneurysm forces.
conclusionIncreased force on the aneurysm is associated with framing coil use, microcatheter placement proximal to aneurysm dome, and slow insertion rate. Further characterization remains necessary to reduce IOR risk, especially concerning the contributions of insertion rate.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.