Evidence map›Paper›PMID 25173625›Full record

ArticleEuropean radiology2014

Comparison of image quality between 70 kVp and 80 kVp: application to paediatric cardiac CT.

Sébastien Durand, Jean-François Paul

Abstract readComparative StudyEvaluation Study
PubMed Publisher
In one paragraph

Article in European radiology, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Sébastien DurandRadiology Department, Centre Chirurgical Marie Lannelongue, 133 Avenue de la Résistance, 92350, Le Plessis-Robinson, France.
Jean-François Paul

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate noise level and contrast-to-noise ratio (CNR) with various kVp-mAs pairs producing the same computed tomography dose index (CTDI) value. The 80 kVp and new 70-kVp settings were compared. MATERIALS AND

methodsThe noise was measured in 10 ovoid water phantoms with different diameters from 10 cm to 28 cm. Contrast was obtained from CTs of iodine-filled tubes. Spiral acquisition protocols at 70 kVp and 80 kVp, with the same CTDI, were applied. In the clinical study, two matched groups, each of 21 paediatric patients, underwent 70-kVp or 80-kVp ECG-gated iodinated-enhanced sequential CT.

resultsNoise was significantly higher with 70 kVp than 80-kVp settings for all phantom sizes. Estimated CNR with phantoms was higher at 70 kVp than 80 kVp, and the difference decreased from 17% to 3% as phantom size increased. The mean CNR in paediatric patients was 15.2 at 70 kVp and 14.3 at 80 kVp (ns). The CNR difference was significantly larger in the small-child subgroup.

conclusionNoise level is slightly higher at the 70-kVp than the 80-kVp setting, but the CNR is higher, particularly for small children. Therefore, 70 kVp may be appropriate for contrast-enhanced CT examinations and 80 kVp for non-enhanced CT in small children. KEY POINTS: 70-kVp settings provide a slightly higher noise level compared to 80-kVp settings. The CNR is higher with 70-kVp than with 80-kVp settings. Without contrast, 80-kVp settings may be preferable over 70-kVp settings.

Indexed as

Signal-To-Noise RatioChildChild, PreschoolContrast MediaHeart Defects, CongenitalHumansInfantInfant, NewbornIodinePhantoms, ImagingRadiation DosageTomography, X-Ray ComputedContrast MediaIodine

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.