Evidence map›Paper›PMID 25173111›Full record

ArticleClinical research in cardiology : official journal of the German Cardiac Society2015

Feasibility of second-generation bioresorbable vascular scaffold implantation in complex anatomical and clinical scenarios.

Milosz Jaguszewski, Jelena-Rima Ghadri, Manuel Zipponi, Dana Roxana Bataiosu, Johanna Diekmann, Verena Geyer, Catharina Anna Neumann, Mia Aurelia Huber, Christian Hagl, Paul Erne and 2 more

Abstract readMulticenter Study
In one paragraph

Article in Clinical research in cardiology : official journal of the German Cardiac Society, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Bioresorbable vascular scaffold implantation to bail out nail gun injury in ST-segment myocardial infarction.Clinical research in cardiology : official journal of the German Cardiac Society · 2018
    Article
  2. Article
  3. Use of a bioresorbable novolimus eluting vascular scaffold fails a hybrid PCI strategy with drug eluting stent.Clinical research in cardiology : official journal of the German Cardiac Society · 2017
    Article
  4. Review
  5. Article
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Milosz JaguszewskiUniversity Heart Center, University Hospital Zurich, Raemistr. 100, 8091, Zurich, Switzerland, milosz.jaguszewski@usz.ch.
Jelena-Rima Ghadri
Manuel Zipponi
Dana Roxana Bataiosu
Johanna Diekmann
Verena Geyer
Catharina Anna Neumann
Mia Aurelia Huber
Christian Hagl
Paul Erne
Thomas F Lüscher
Christian Templin

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundBioresorbable vascular scaffolds (BVS) have become an emerging tool to treat coronary artery disease. However, the current use of BVS is still widely restricted to stable patients and non-complex lesions. In real-world practice patients are far more complex than those with simple type A lesions and the extended use of BVS to complex lesions and high-risk patients needs to be evaluated. Therefore, we sought to investigate the feasibility and performance of BVS in a broad spectrum of patients.

methods106 patients underwent in total 193 BVS implantations. We assessed the device-related (cardiac death, target vessel myocardial infarction, ischemia-driven target lesion revascularization) and patient-related (all-cause death, any reinfarction and any revascularization) composite outcomes.

results90 % of patients (n = 95) had at least one of the following characteristics: >65 years (35 %), ACS (42 %), tortuous vessels (13 %), calcified (17 %) or thrombotic lesions (12 %), lesions defined as AHA type B2/C (42 %), bifurcations (16 %), chronic total occlusions (9 %) or restenosis (14 %). There was no evidence of significant edge dissection, huge thrombus load or incidence of scaffold dislodgement or scaffold disruption in optical coherence tomography pullbacks. Out of 10,157 struts evaluated within 1,117 cross-sections, 302 were classified as malapposed (2.9 %). During a mean follow-up of 147 ± 119 days the rate of device-related events was 2.0 %, whereas patient-related composite events occurred in 6.1 %.

conclusionsOur results strongly suggest that BVS implantation is feasible in a wide spectrum of patients and complex anatomy of coronary lesions. Long-term outcome of BVS should be further investigated in unrestricted settings in randomized controlled trials.

Indexed as

Absorbable ImplantsBlood Vessel ProsthesisDrug-Eluting StentsAdultAgedCoronary Artery DiseaseEquipment Failure AnalysisEverolimusFeasibility StudiesFemaleHumansImmunosuppressive AgentsMaleMiddle AgedProsthesis DesignRetrospective StudiesEverolimusImmunosuppressive AgentsSirolimus

Identifiers

PMID25173111
PMCPMC4315475

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.