Evidence map›Paper›PMID 25170844›Full record

ArticlePloS one2014

Optimal iodine staining of cardiac tissue for X-ray computed tomography.

Timothy D Butters, Simon J Castro, Tristan Lowe, Yanmin Zhang, Ming Lei, Philip J Withers, Henggui Zhang

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.1field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Article
  6. Review
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Timothy D ButtersSchool of Physics and Astronomy, The University of Manchester, Manchester, Greater Manchester, United Kingdom.
Simon J CastroSchool of Physics and Astronomy, The University of Manchester, Manchester, Greater Manchester, United Kingdom.
Tristan LoweSchool of Materials Science, The University of Manchester, Manchester, Greater Manchester, United Kingdom.
Yanmin ZhangInstitute of Cardiovascular Sciences, Faculty of Medical and Human Sciences, The University of Manchester, Manchester, Greater Manchester, United Kingdom; Department of Pharmacology, University of Oxford, Oxford, Oxfordshire, United Kingdom.
Ming LeiInstitute of Cardiovascular Sciences, Faculty of Medical and Human Sciences, The University of Manchester, Manchester, Greater Manchester, United Kingdom; Department of Pharmacology, University of Oxford, Oxford, Oxfordshire, United Kingdom.
Philip J WithersSchool of Materials Science, The University of Manchester, Manchester, Greater Manchester, United Kingdom.
Henggui ZhangSchool of Physics and Astronomy, The University of Manchester, Manchester, Greater Manchester, United Kingdom.
University of Manchester · GB

Funding

British Heart Foundation PG/11/59/29006Medical Research Council G1002647
6 · The paper itself

Abstract

X-ray computed tomography (XCT) has been shown to be an effective imaging technique for a variety of materials. Due to the relatively low differential attenuation of X-rays in biological tissue, a high density contrast agent is often required to obtain optimal contrast. The contrast agent, iodine potassium iodide ([Formula: see text]), has been used in several biological studies to augment the use of XCT scanning. Recently I2KI was used in XCT scans of animal hearts to study cardiac structure and to generate 3D anatomical computer models. However, to date there has been no thorough study into the optimal use of I2KI as a contrast agent in cardiac muscle with respect to the staining times required, which has been shown to impact significantly upon the quality of results. In this study we address this issue by systematically scanning samples at various stages of the staining process. To achieve this, mouse hearts were stained for up to 58 hours and scanned at regular intervals of 6-7 hours throughout this process. Optimal staining was found to depend upon the thickness of the tissue; a simple empirical exponential relationship was derived to allow calculation of the required staining time for cardiac samples of an arbitrary size.

Indexed as

AlgorithmsAnimalsContrast MediaHeartIodineIodine CompoundsMiceMyocardiumPericardiumReproducibility of ResultsStaining and LabelingTime FactorsTomography, X-Ray ComputedContrast MediaIodineIodine Compoundsiodine potassium iodide

Identifiers

PMID25170844
PMCPMC4149378
OpenAlexW2063963132

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked