ArticleNetherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation2014
Follow-up of implantable cardioverter-defibrillator therapy: comparison of coronary artery disease and dilated cardiomyopathy.
Article in Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Predicting appropriate shocks in patients with heart failure: Patient level meta-analysis from SCD-HeFT and MADIT II.Journal of cardiovascular electrophysiology · 2017Pooled it
- Tachycardia Therapy Outcomes of Ischemic Versus Nonischemic Cardiomyopathy on Cardiac Resynchronization Therapy: A Propensity Score-matched Analysis.Journal of community hospital internal medicine perspectives · 2023Article
- Implantable Cardioverter Defibrillator in Primary and Secondary Prevention of SCD-What We Still Don't Know.Journal of cardiovascular development and disease · 2022Review
- Comparable Efficacy in Ischemic and Non-Ischemic ICD Recipients for the Primary Prevention of Sudden Cardiac Death.Biomedicines · 2021Article
- Increased mortality and ICD therapies in ischemic versus non-ischemic dilated cardiomyopathy patients with cardiac resynchronization having survived until first device replacement.Archives of medical science : AMS · 2019Article
- Echo response and clinical outcome in CRT patients.Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation · 2016Article
- A call for re-evaluation of the guidelines for prophylactic ICD implantation.Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation · 2014Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeSince several large trials have proven the effectiveness of implantable cardioverter-defibrillators (ICDs) in patients with left ventricular dysfunction, disadvantages have become more apparent. As the prognosis of patients with cardiovascular diseases is improving, assessment of ICD patients and re-evaluation of the current guidelines is mandatory. We aimed to evaluate differences in mortality and occurrence of (in)appropriate shocks in ICD patients with coronary artery disease (CAD) or dilated cardiomyopathy (DCM).
methodsIn a large teaching hospital, all consecutive patients with systolic dysfunction due to CAD or DCM who received an ICD with and without resynchronisation therapy, were collected in a database.
resultsA total of 320 consecutive patients (age 67 ± 10 years) were classified as CAD patients and 178 (63 ± 11 years) as DCM patients. Median follow-up was 40 months (interquartile range [IQR] 23─57 months). All-cause mortality was 14 % (CAD 15 % vs DCM 13 %). Appropriate shocks occurred in 13 % of all patients (CAD 15 % vs DCM 11 %, p = 0.12) and inappropriate shocks occurred in 10 % (CAD 8 % vs DCM 12 %, p = 0.27). Multivariate analysis demonstrated impaired left ventricular ejection fraction, QRS >120, age ≥75 years and low estimated glomerular filtration rate as predictors for all-cause mortality. Predictors for inappropriate shocks were permanent and paroxysmal atrial fibrillation.
conclusionMortality rates were similar in patients with CAD and DCM who received an ICD. Furthermore, no differences were found in the occurrence of appropriate and inappropriate ICD interventions between these patient groups.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.