ArticleThe British journal of radiology2014
Implementation of a target volume design function for intrafractional range variation in a particle beam treatment planning system.
Article in The British journal of radiology, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Carbon-ion pencil beam scanning for thoracic treatment - initiation report and dose metrics evaluation.Journal of radiation research · 2016Trial
- Commissioning and robustness evaluation of external laser sensor for respiratory gating in carbon-ion radiotherapy.Journal of applied clinical medical physics · 2026Article
- Optimizing 3DCT image registration for interfractional changes in carbon-ion prostate radiotherapy.Scientific reports · 2023Article
- AAPM Task Group Report 290: Respiratory motion management for particle therapy.Medical physics · 2022Article
- Beam direction arrangement using a superconducting rotating gantry in carbon ion treatment for pancreatic cancer.The British journal of radiology · 2019Article
- Evolution of Carbon Ion Radiotherapy at the National Institute of Radiological Sciences in Japan.Cancers · 2018Review
- Density overwrites of internal tumor volumes in intensity modulated proton therapy plans for mobile lung tumors.Physics in medicine and biology · 2018Article
- Gating window dependency on scanned carbon-ion beam dose distribution and imaging dose for thoracoabdominal treatment.The British journal of radiology · 2017Article
- Dose escalation study with respiratory-gated carbon-ion scanning radiotherapy using a simultaneous integrated boost for pancreatic cancer: simulation with four-dimensional computed tomography.The British journal of radiology · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveTreatment planning for charged particle therapy in the thoracic and abdominal regions should take account of range uncertainty due to intrafractional motion. Here, we developed a design tool (4Dtool) for the target volume [field-specific target volume (FTV)], which accounts for this uncertainty using four-dimensional CT (4DCT).
methodsTarget and normal tissue contours were input manually into a treatment planning system (TPS). These data were transferred to the 4Dtool via the picture archiving and communication system (PACS). Contours at the reference phase were propagated to other phases by deformable image registration. FTV was calculated using 4DCT on the 4Dtool. The TPS displays FTV contours using digital imaging and communications in medicine files imported from the PACS. These treatment parameters on the CT image at the reference phase were then used for dose calculation on the TPS. The tool was tested in single clinical case randomly selected from patients treated at our centre for lung cancer.
resultsIn this clinical case, calculation of dose distribution with the 4Dtool resulted in the successful delivery of carbon-ion beam at the reference phase of 95% of the prescribed dose to the clinical target volume (CTV). Application to the other phases also provided sufficient dose to the CTV.
conclusionThe 4Dtool software allows the design of the target volume with consideration to intrafractional range variation and is now in routine clinical use at our institution. ADVANCES IN KNOWLEDGE: Our alternative technique represents a practical approach to four-dimensional treatment planning within the current state of charged particle therapy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.