Evidence map›Paper›PMID 25166472›Full record

ArticleJournal of biomedical optics2014

Reduced temporal sampling effect on accuracy of time-domain fluorescence lifetime Förster resonance energy transfer.

Travis Omer, Lingling Zhao, Xavier Intes, Juergen Hahn

Abstract read
In one paragraph

Article in Journal of biomedical optics, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. AlliGator: A Phasor Computational Platform for FastOptical molecular probes, imaging and drug delivery · 2017
    Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Travis OmerRensselaer Polytechnic Institute, Department of Biomedical Engineering, 110 8th Street, Troy, New York 12180, United States.
Lingling ZhaoRensselaer Polytechnic Institute, Department of Biomedical Engineering, 110 8th Street, Troy, New York 12180, United States.
Xavier IntesRensselaer Polytechnic Institute, Department of Biomedical Engineering, 110 8th Street, Troy, New York 12180, United States.
Juergen HahnRensselaer Polytechnic Institute, Departments of Biomedical Engineering and Chemical & Biological Engineering, 110 8th Street, Troy, New York 12180, United States.

Funding

The 3D whole Body Distribution of NIR transferrin using FRET tomography imagingR21CA161782 · NCI · ALBANY MEDICAL COLLEGE · PI BARROSO, MARGARIDA · 2011 to 2012
$379k
Multispectral Fluorescence Molecular Tomography with Structured LightR21EB013421 · NIBIB · RENSSELAER POLYTECHNIC INSTITUTE · PI INTES, XAVIER · 2012 to 2013
$369k
NCI NIH HHS R21 CA161782NIBIB NIH HHS R21 EB013421
6 · The paper itself

Abstract

Fluorescence lifetime imaging (FLIM) aims at quantifying the exponential decay rate of fluorophores to yield lifetime maps over the imaged sample. When combined with Förster resonance energy transfer (FRET), the technique can be used to indirectly sense interactions at the nanoscale such as protein–protein interactions, protein–DNA interactions, and protein conformational changes. In the case of FLIM-FRET, the fluorescence intensity decays are fitted to a biexponential model in order to estimate the lifetime and fractional amplitude coefficients of each component of the population of the donor fluorophore (quenched and nonquenched). Numerous time data points, also called temporal or time gates, are typically employed for accurately estimating the model parameters, leading to lengthy acquisition times and significant computational demands. This work investigates the effect of the number and location of time gates on model parameter estimation accuracy. A detailed model of a FLIM-FRET imaging system is used for the investigation, and the simulation outcomes are validated with in vitro and in vivo experimental data. In all cases investigated, it is found that 10 equally spaced time gates allow robust estimation of model-based parameters with accuracy similar to that of full temporal datasets (90 gates).

Indexed as

AlgorithmsArtifactsAnimalsData Interpretation, StatisticalDogsFluorescence Resonance Energy TransferImage EnhancementImage Interpretation, Computer-AssistedMadin Darby Canine Kidney CellsMicroscopy, FluorescenceMolecular ImagingReproducibility of ResultsSample SizeSensitivity and Specificity

Identifiers

PMID25166472
PMCPMC4147194

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.