ArticleThe international journal of cardiovascular imaging2015
Effective diameter of the aortic annulus prior to transcatheter aortic valve implantation: influence of area-based versus perimeter-based calculation.
Article in The international journal of cardiovascular imaging, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 25 citations in OpenAlex.
- Large extracellular vesicle (EV) and neutrophil extracellular trap (NET) interaction captured in vivo during systemic inflammation.Scientific reports · 2024Article
- Recommendations in pre-procedural imaging assessment for TAVI intervention: SIC-SIRM position paper part 2 (CT and MR angiography, standard medical reporting, future perspectives).La Radiologia medica · 2022Article
- Aortic annulus sizing in bicuspid and tricuspid aortic valves using CT in patients with surgical aortic valve replacement.Scientific reports · 2021Article
- Computed tomography guided sizing for transcatheter pulmonary valve replacement.International journal of cardiology. Heart & vasculature · 2020Article
- Cardiac Computed Tomography - More Than Coronary Arteries? A Clinical Update.RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin · 2019Review
- 3D-assessment of RVOT dimensions prior percutaneous pulmonary valve implantation: comparison of contrast-enhanced magnetic resonance angiography versus 3D steady-state free precession sequence.The international journal of cardiovascular imaging · 2019Article
- Assessment of aortic valve tract dynamics using automatic tracking of 3D transesophageal echocardiographic images.The international journal of cardiovascular imaging · 2019Article
- Do CTA measurements of annular diameter, perimeter and area result in different TAVI prosthesis sizes?The international journal of cardiovascular imaging · 2018Article
- Role of Imaging in Transcatheter Aortic Valve Replacement.Current treatment options in cardiovascular medicine · 2016Review
- Cardiovascular imaging 2015 in the International Journal of Cardiovascular Imaging.The international journal of cardiovascular imaging · 2016Review
- Vascular Imaging Before Transcatheter Aortic Valve Replacement (TAVR): Why and How?Current cardiology reports · 2016Review
- Cardiovascular imaging 2014 in the International Journal of Cardiovascular Imaging.The international journal of cardiovascular imaging · 2015Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In computed tomography (CT) evaluation prior to transcatheter aortic valve implantation area- and perimeter-based calculation of the aortic annulus diameter, the so-called effective annulus diameter (ED), is the preferred parameter for decision making regarding prosthesis sizes. Currently, it is unclear how relevant the differences between the two methods of measurement are and how they are influenced by the cardiac cycle. The aim of this study was to compare area- and perimeter-based measurements in computed tomography derived aortic annulus sizing. A total of 60 patients who underwent evaluation for transcatheter aortic valve implantation were included in this study. All patients received pre-procedural ECG gated CT. The aortic annulus area and perimeter were measured and the derived ED compared using parametric statistics and Bland and Altman analysis. The mean patient age was 80.2 ± 4 years. Systolic aortic annulus area and perimeter were higher compared to diastolic results (mean difference area 12.8 ± 24 mm(2) and perimeter 0.72 ± 1 mm; p = 0.009-0.068). Both the area- and perimeter-based ED had a good agreement within two standard deviations for systolic and diastolic measurements. Effective diameter measurements derived from the area were significantly smaller compared to perimeter-based measurements (mean difference: systolic 0.72 ± 0.3 mm and diastolic 0.81 ± 0.4 mm; p < 0.001). While the area-based ED was significantly influenced by the cardiac cycle with a mean difference of 0.4 ± 0.6 mm (p = 0.009), no significant difference was found for the perimeter-based ED (mean difference: 0.2 ± 0.4; p = 0.07). For patients undergoing CT evaluation prior to transcatheter aortic valve implantation, the perimeter-based effective annulus diameter provides a reliable parameter for annulus sizing without significant affection by the cardiac cycle and therefore facilitates annulus measurements with a single heart phase. However, perimeter-based diameters of the annulus are significantly larger than area-based diameters.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.