Evidence map›Paper›PMID 25152591›Full record

ArticleWorld journal of gastroenterology2014

Electrochemiluminescence immunoassay method underestimates cortisol suppression in ulcerative colitis patients treated with oral prednisone.

Francesco Manguso, Raffaele Bennato, Giovanni Lombardi, Assunta Viola, Elisabetta Riccio, Livio Cipolletta

Open access · hybridAbstract readComparative Study
In one paragraph

Article in World journal of gastroenterology, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
0.9field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 8 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Francesco MangusoFrancesco Manguso, Raffaele Bennato, Giovanni Lombardi, Elisabetta Riccio, Livio Cipolletta, Division of Gastroenterology, Cardarelli Hospital, Naples 80131, Italy.
Raffaele BennatoFrancesco Manguso, Raffaele Bennato, Giovanni Lombardi, Elisabetta Riccio, Livio Cipolletta, Division of Gastroenterology, Cardarelli Hospital, Naples 80131, Italy.
Giovanni LombardiFrancesco Manguso, Raffaele Bennato, Giovanni Lombardi, Elisabetta Riccio, Livio Cipolletta, Division of Gastroenterology, Cardarelli Hospital, Naples 80131, Italy.
Assunta ViolaFrancesco Manguso, Raffaele Bennato, Giovanni Lombardi, Elisabetta Riccio, Livio Cipolletta, Division of Gastroenterology, Cardarelli Hospital, Naples 80131, Italy.
Elisabetta RiccioFrancesco Manguso, Raffaele Bennato, Giovanni Lombardi, Elisabetta Riccio, Livio Cipolletta, Division of Gastroenterology, Cardarelli Hospital, Naples 80131, Italy.
Livio CipollettaFrancesco Manguso, Raffaele Bennato, Giovanni Lombardi, Elisabetta Riccio, Livio Cipolletta, Division of Gastroenterology, Cardarelli Hospital, Naples 80131, Italy.
Fatebenefratelli Hospital · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimTo evaluate cortisolemia by using conventional electrochemiluminescence immunoassay (ECLIA) method compared to liquid chromatography-tandem mass spectrometry (LC-MS/MS) method in active ulcerative colitis (UC) patients treated with oral prednisone (PD).

methodsTwenty patients (12 males) with acute relapse of UC started oral PD at a dose of 40 mg once a day, tapered of 10 mg every 2 wk. When a stable 2-wk daily dose of 30 mg was reached, blood samples for cortisol levels' measurement were drawn in the morning in fasting conditions to determine circulating cortisol by LC-MS/MS and ECLIA assay.

resultsMedian interquartile range cortisolemia with ECLIA and LC-MS/MS method was 54.1 (185.8) nmol/L and 32.1 (124.0) nmol/L, respectively (P < 0.001). The within-patient median differences between the two methods was 23.2 (40.6) nmol/L, with higher cortisol levels for the ECLIA method. The estimated geometric mean ratio between methods was 1.85 (95%CI: 2.39-1.43) considering all data or 1.58 (95%CI: 2.30-1.09) considering only data above the limit of quantification (n = 12). The 95%CIs of the geometric mean ratio between methods confirm a statistically significant difference.

conclusionBlood cortisol levels detected with ECLIA method seems to be higher than the ones measured by LC-MS/MS, indicating a possible overestimation of them in patients treated with PD. Therefore, the cortisol suppression in patients under treatment with oral PD should not be measured using ECLIA method.

Indexed as

Electrochemical TechniquesLuminescent MeasurementsAdministration, OralAdultAnti-Inflammatory AgentsBiomarkersChromatography, LiquidColitis, UlcerativeDown-RegulationDrug Administration ScheduleFemaleGastrointestinal AgentsHumansHydrocortisoneImmunoassayMaleAnti-Inflammatory AgentsBiomarkersGastrointestinal AgentsHydrocortisonePrednisoneCortisolImmunoassayLiquid chromatographyPrednisoneTandem mass spectrometryUlcerative colitis

Identifiers

PMID25152591
PMCPMC4138468
OpenAlexW2048818357

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.