Evidence map›Paper›PMID 25140634›Full record

ArticleSensors (Basel, Switzerland)2014

Rapid, single-molecule assays in nano/micro-fluidic chips with arrays of closely spaced parallel channels fabricated by femtosecond laser machining.

Brian K Canfield, Jason K King, William N Robinson, William H Hofmeister, Lloyd M Davis

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Brian K CanfieldCenter for Laser Applications, University of Tennessee Space Institute, 411 B. H. Goethert Parkway, MS 35, Tullahoma, TN 37388, USA. bcanfiel@utsi.edu.
Jason K KingCenter for Laser Applications, University of Tennessee Space Institute, 411 B. H. Goethert Parkway, MS 35, Tullahoma, TN 37388, USA. jason.king@nist.gov.
William N RobinsonCenter for Laser Applications, University of Tennessee Space Institute, 411 B. H. Goethert Parkway, MS 35, Tullahoma, TN 37388, USA. quantum.penguin@gmail.com.
William H HofmeisterCenter for Laser Applications, University of Tennessee Space Institute, 411 B. H. Goethert Parkway, MS 35, Tullahoma, TN 37388, USA. whofmeis@utsi.edu.
Lloyd M DavisCenter for Laser Applications, University of Tennessee Space Institute, 411 B. H. Goethert Parkway, MS 35, Tullahoma, TN 37388, USA. ldavis@utsi.edu.

Funding

High Throughput Modular Microfluidic Systems for Drug Discovery/DevelopmentR01EB006639 · NIBIB · LOUISIANA STATE UNIV A&M COL BATON ROUGE · PI SOPER, STEVEN ALLAN · 2007 to 2010
$2.6M
NIBIB NIH HHS EB-006639NIBIB NIH HHS R01 EB006639
6 · The paper itself

Abstract

Cost-effective pharmaceutical drug discovery depends on increasing assay throughput while reducing reagent needs. To this end, we are developing an ultrasensitive, fluorescence-based platform that incorporates a nano/micro-fluidic chip with an array of closely spaced channels for parallelized optical readout of single-molecule assays. Here we describe the use of direct femtosecond laser machining to fabricate several hundred closely spaced channels on the surfaces of fused silica substrates. The channels are sealed by bonding to a microscope cover slip spin-coated with a thin film of poly(dimethylsiloxane). Single-molecule detection experiments are conducted using a custom-built, wide-field microscope. The array of channels is epi-illuminated by a line-generating red diode laser, resulting in a line focus just a few microns thick across a 500 micron field of view. A dilute aqueous solution of fluorescently labeled biomolecules is loaded into the device and fluorescence is detected with an electron-multiplying CCD camera, allowing acquisition rates up to 7 kHz for each microchannel. Matched digital filtering based on experimental parameters is used to perform an initial, rapid assessment of detected fluorescence. More detailed analysis is obtained through fluorescence correlation spectroscopy. Simulated fluorescence data is shown to agree well with experimental values.

Indexed as

Biological AssayLasersMicrofluidic Analytical TechniquesNanotechnologySpectrometry, Fluorescence

Identifiers

PMID25140634
PMCPMC4178987

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.