Evidence map›Paper›PMID 25128960›Full record

ArticleGraefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie2015

Retinal vessel diameter measurements by spectral domain optical coherence tomography.

Yanling Ouyang, Qing Shao, Dirk Scharf, Antonia M Joussen, Florian M Heussen

Abstract read
PubMed Publisher
In one paragraph

Article in Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
2.1field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 41 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Trial
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Automated Retinal Vein Cannulation on Silicone Phantoms Using Optical-Coherence-Tomography-Guided Robotic Manipulations.IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division · 2021
    Article
  11. Article
  12. Article
  13. Retinal OCT Denoising with Pseudo-Multimodal Fusion Network.Ophthalmic medical image analysis : 7th International Workshop, OMIA 2020, held in conjunction with MICCAI 2020, Lima, Peru, October 8, 2020, proceedings · 2020
    Article
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Yanling OuyangDepartment of Ophthalmology, Charité-University Medicine Berlin, Augustenburger Platz 1, 13353, Berlin, Germany.
Qing Shao
Dirk Scharf
Antonia M Joussen
Florian M Heussen
Charité - Universitätsmedizin Berlin · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo describe a spectral domain optical coherence (OCT)-assisted method of measuring retinal vessel diameters.

methodsAll Patients with an OCT circle scan centered at the optic nerve head using a Spectralis OCT (Heidelberg Engineering, Heidelberg, Germany) were retrospectively reviewed. Individual retinal vessels were identified on infrared reflectance (IR) images and given unique labels both on IR and spectral domain OCT (SD-OCT). Vessel width and vessel types obtained by IR were documented as ground truth. From OCT, measurements of each vessel, including horizontal vessel contour diameter, vertical vessel contour diameter, horizontal hyperreflective core diameter, and reflectance shadowing width, were assessed.

resultsA total of 220 vessels from 13 eyes of 12 patients were labeled, among which, 194 vessels (88 arteries and 65 veins confirmed from IR) larger than 40 microns were included in the study. The mean vessel width obtained from IR was 107.9 ± 36.1 microns. A mean vertical vessel contour diameter of 119.6 ± 29.9 microns and a mean horizontal vessel contour diameter of 124.1 ± 31.1 microns were measured by SD-OCT. Vertical vessel contour diameter did not differ from vessel width in all subgroup analysis. Horizontal vessel contour diameter was not significantly different from vessel width for arteries and had strong or very strong correlation with vessel width for veins.

conclusionIn our study, vertical vessel contour diameter measured by current commercially available SD-OCT was consistent with vessel width obtained by IR with good reproducibility. This SD-OCT based method could potentially be used as a standard measurement procedure to evaluate retinal vessel diameters and their changes in ocular and systemic disorders.

Indexed as

Diagnostic Techniques, OphthalmologicalAdultAgedAged, 80 and overDiabetic RetinopathyFemaleHumansMacular DegenerationMaleMiddle AgedObserver VariationOptic DiskOrgan SizeReproducibility of ResultsRetinal ArteryRetinal Vein

Identifiers

PMID25128960
OpenAlexW2078331375

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.