ArticleSensors (Basel, Switzerland)2014
Flexible capacitive electrodes for minimizing motion artifacts in ambulatory electrocardiograms.
Article in Sensors (Basel, Switzerland), 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 31 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
31 citing papers in PubMed.
- Improving Signal Quality in Non-Contact Electrocardiography: Novel Strategy for Motion Artifact Reduction.Sensors (Basel, Switzerland) · 2026Article
- Multiscale Engineering of Ion-Conducting Gels for Sustainable Bioelectronic Systems.Small methods · 2026Review
- Design and Assessment of Flexible Capacitive Electrodes for Reusable ECG Monitoring: Effects of Sweat and Adapted Front-End Configuration.Sensors (Basel, Switzerland) · 2025Article
- Drunk Driver Detection Using Multiple Non-Invasive Biosignals.Sensors (Basel, Switzerland) · 2025Article
- A New Self-Made 16-Channel Capacitive Electrocardiography System: An Investigation and Validation for Non-Contact Electrodes.Sensors (Basel, Switzerland) · 2025Article
- Motion artifacts in capacitive ECG monitoring systems: a review of existing models and reduction techniques.Medical & biological engineering & computing · 2024Review
- Electrospun Rubber Nanofiber Web-Based Dry Electrodes for Biopotential Monitoring.Sensors (Basel, Switzerland) · 2023Article
- Recent Advances in Stretchable and Wearable Capacitive Electrophysiological Sensors for Long-Term Health Monitoring.Biosensors · 2022Review
- Flexible Non-contact Electrodes for Wearable Biosensors System on Electrocardiogram Monitoring in Motion.Frontiers in neuroscience · 2022Article
- Noise-Reducing Fabric Electrode for ECG Measurement.Sensors (Basel, Switzerland) · 2021Article
- Wearable Smart Textiles for Long-Term Electrocardiography Monitoring-A Review.Sensors (Basel, Switzerland) · 2021Review
- Novel Stable Capacitive Electrocardiogram Measurement System.Sensors (Basel, Switzerland) · 2021Article
- Common-Mode Voltage Reduction in Capacitive Sensing of Biosignal Using Capacitive Grounding and DRL Electrode.Sensors (Basel, Switzerland) · 2021Article
- Elderly Perception on the Internet of Things-Based Integrated Smart-Home System.Sensors (Basel, Switzerland) · 2021Article
- Non-Contact Measurements of Electrocardiogram and Cough-Associated Electromyogram from the Neck Using In-Pillow Common Cloth Electrodes: A Proof-of-Concept Study.Sensors (Basel, Switzerland) · 2021Article
- Development of Washable Silver Printed Textile Electrodes for Long-Term ECG Monitoring.Sensors (Basel, Switzerland) · 2020Article
- Contactless Capacitive Electrocardiography Using Hybrid Flexible Printed Electrodes.Sensors (Basel, Switzerland) · 2020Article
- Electrode Humidification Design for Artifact Reduction in Capacitive ECG Measurements.Sensors (Basel, Switzerland) · 2020Article
- Noise-Resistant CECG Using Novel Capacitive Electrodes.Sensors (Basel, Switzerland) · 2020Article
- Adaptive Motion Artifact Reduction Based on Empirical Wavelet Transform and Wavelet Thresholding for the Non-Contact ECG Monitoring Systems.Sensors (Basel, Switzerland) · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study proposes the use of flexible capacitive electrodes for reducing motion artifacts in a wearable electrocardiogram (ECG) device. The capacitive electrodes have conductive foam on their surface, a shield, an optimal input bias resistor, and guarding feedback. The electrodes are integrated in a chest belt, and the acquired signals are transmitted wirelessly for ambulatory heart rate monitoring. We experimentally validated the electrode performance with subjects standing and walking on a treadmill at speeds of up to 7 km/h. The results confirmed the highly accurate heart rate detection capacity of the developed system and its feasibility for daily-life ECG monitoring.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.