ArticleMedical & biological engineering & computing2016
Multiplane spectroscopic whole-body photoacoustic imaging of small animals in vivo.
Article in Medical & biological engineering & computing, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 58 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
58 citing papers in PubMed.
- A comprehensive review of high-performance photoacoustic microscopy systems.Photoacoustics · 2025Review
- Multifunctional Upconversion Nanoparticles Transforming Photoacoustic Imaging: A Review.Nanomaterials (Basel, Switzerland) · 2025Review
- Review on Multispectral Photoacoustic Imaging Using Stimulated Raman Scattering Light Sources.Sensors (Basel, Switzerland) · 2025Review
- Full-view volumetric photoacoustic imaging using a hemispheric transducer array combined with an acoustic reflector.Biomedical optics express · 2024Article
- 3D Multiparametric Photoacoustic Computed Tomography of Primary and Metastatic Tumors in Living Mice.ACS nano · 2024Article
- Real-time dual-modal photoacoustic and fluorescence small animal imaging.Photoacoustics · 2024Article
- An ultrasensitive and broadband transparent ultrasound transducer for ultrasound and photoacoustic imaging in-vivo.Nature communications · 2024Article
- Enhancing photoacoustic imaging for lung diagnostics and BCI communication: simulation of cavity structures artifact generation and evaluation of noise reduction techniques.Frontiers in bioengineering and biotechnology · 2024Article
- Automated Laser-Fiber Coupling Module for Optical-Resolution Photoacoustic Microscopy.Sensors (Basel, Switzerland) · 2023Article
- Spiral volumetric optoacoustic tomography for imaging whole-body biodynamics in small animals.Nature protocols · 2023Review
- Functional photoacoustic imaging: from nano- and micro- to macro-scale.Nano convergence · 2023Review
- Review on ultrasound-guided photoacoustic imaging for complementary analyses of biological systemsExperimental biology and medicine (Maywood, N.J.) · 2023Review
- Head-to-tail imaging of mice with spiral volumetric optoacoustic tomography.Photoacoustics · 2023Article
- Recent Advances in Photoacoustic Agents for Theranostic Applications.Nanomaterials (Basel, Switzerland) · 2023Review
- Switchable preamplifier for dual modal photoacoustic and ultrasound imaging.Biomedical optics express · 2023Article
- In vivo quantitative photoacoustic evaluation of the liver and kidney pathology in tyrosinemia.Photoacoustics · 2022Article
- Contrast Agents for Photoacoustic Imaging: A Review Focusing on the Wavelength Range.Biosensors · 2022Review
- Whole-Body Photoacoustic Imaging Techniques for Preclinical Small Animal Studies.Sensors (Basel, Switzerland) · 2022Review
- State of the Art in Carbon Nanomaterials for Photoacoustic Imaging.Biomedicines · 2022Review
- Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We have successfully developed a multiscale acoustic-resolution photoacoustic tomography system in a single imaging platform. By switching between ultrasound transducers (center frequencies 5 and 40 MHz) and optical condensers, we have photoacoustically imaged microvasculatures of small animals in vivo at different scales. Further, we have extended the field of view of our imaging system to entire bodies of small animals. At different imaging planes, we have noninvasively imaged the major blood vessels (e.g., descending aorta, intercostal vessels, cephalic vessels, brachial vessels, femoral vessels, popliteal vessels, lateral marginal vessels, cranial mesenteric vessels, mammalian vessels, carotid artery, jugular vein, subclavian vessels, iliac vessels, and caudal vessels) as well as intact internal organs (e.g., spleen, liver, kidney, intestine, cecum, and spinal cord) of the animals in vivo. The spectroscopic whole-body photoacoustic imaging clearly reveals the spectral responses of the internal structures. Similar to other existing preclinical whole-body imaging systems, this whole-body photoacoustic tomography can be a useful tool for small-animal research.
Indexed as
Identifiers
25115270What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.