ArticleMedical devices (Auckland, N.Z.)2014

Sealing vessels up to 7 mm in diameter solely with ultrasonic technology.

Richard W Timm, Ryan M Asher, Karalyn R Tellio, Alissa L Welling, Jeffrey W Clymer, Joseph F Amaral

Registry-linked trialAbstract read
In one paragraph

Article in Medical devices (Auckland, N.Z.), 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05629611 (Efficacy and Safety Evaluation of Advanced Vessel Sealing Device), which is not on this map. Cited by 21 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
21citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05629611 narecruitingnot on this mapstarted 2023, after this paper: background citation

Efficacy and Safety Evaluation of Advanced Vessel Sealing Device (Vi-sealer)

TypeinterventionalSponsorHyun ParkRan2023 to 2025Enrolled280ConditionsBenign Gynecologic NeoplasmArmsVi-Sealer, Ligasure, Other AHD
3 · Its place in the literature

Who cites it

21 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Surgery.Recent results in cancer research. Fortschritte der Krebsforschung. Progres dans les recherches sur le cancer · 2023
    Article
  12. Article
  13. Article
  14. Article
  15. Review
  16. Article
  17. Article
  18. Comparison of Effects of Vessel-Sealing Devices and Conventional Hemorrhoidectomy on Postoperative Pain and Quality of Life.Medical science monitor : international medical journal of experimental and clinical research · 2018
    Article
  19. Article
  20. Hemostasis with the Ultrasonic Scalpel.JSLS : Journal of the Society of Laparoendoscopic Surgeons
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Richard W TimmEthicon Inc., Cincinnati, OH, USA.
Ryan M AsherEthicon Inc., Cincinnati, OH, USA.
Karalyn R TellioEthicon Inc., Cincinnati, OH, USA.
Alissa L WellingEthicon Inc., Cincinnati, OH, USA.
Jeffrey W ClymerEthicon Inc., Cincinnati, OH, USA.
Joseph F AmaralEthicon Inc., Cincinnati, OH, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionUltrasonic energy is a mainstay in the armamentarium of surgeons, providing multifunctionality, precision, and control when dissecting and sealing vessels up to 5 mm in diameter. Historically, the inability to seal vessels in the 5-7 mm range has been perceived as an inherent limitation of ultrasonic technology. The purpose of this study was to evaluate sealing of vessels up to 7 mm in diameter with an ultrasonic device that modulates energy delivery during the sealing period.

methodsIn ex vivo benchtop and in vivo acute and survival preclinical models, a new ultrasonic device, Harmonic ACE(®)+7 Shears (Harmonic 7), was compared with advanced bipolar devices in sealing vessels 1-7 mm in diameter with respect of burst pressure, seal reliability, and seal durability. Lateral thermal damage and transection time were also evaluated.

resultsEx vivo tests of Harmonic 7 demonstrated significantly greater median burst pressures than an advanced bipolar device both for vessels <5 mm in diameter (1,078 mmHg and 836 mmHg, respectively, P=0.046) and for those in the range of 5-7 mm (1,419 mmHg and 591 mmHg, P<0.001). In vivo tests in porcine and caprine models demonstrated similar rates of hemostasis between Harmonic 7 and advanced bipolar devices, with high success rates at initial transection and seal durability of 100% after a 30-day survival period.

conclusionSealing 5-7 mm vessels is not a limitation of the type of energy used but of how energy is delivered to tissue. These studies document the ability of ultrasonic energy alone to reliably seal large vessels 5-7 mm in diameter, with significantly greater burst pressure observed in in vitro studies than those observed with an advanced bipolar technology when energy delivery is modulated during the sealing cycle. Furthermore, the seals created in 5-7 mm vessels are shown to be reliable and durable in in vivo preclinical studies.

Indexed as

7 mmburst pressureHarmonicultrasonicvessel sealing

Identifiers

PMID25114600