Evidence map›Paper›PMID 25110699›Full record

Trial reportBioMed research international2014

Cementless fixation of osteoporotic VCFs using titanium mesh implants (OsseoFix): preliminary results.

Anica Eschler, Stephan Albrecht Ender, Benjamin Ulmar, Philipp Herlyn, Thomas Mittlmeier, Georg Gradl

Open access · hybridAbstract readClinical Trial
In one paragraph

Trial report in BioMed research international, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
1.5field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 23 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Review
  5. Review
  6. Article
  7. Article
  8. Review
  9. Review
  10. Review
  11. Review
  12. Third-generation percutaneous vertebral augmentation systems.Journal of spine surgery (Hong Kong) · 2016
    Review
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Anica EschlerDepartment of Trauma, Hand and Reconstructive Surgery, University of Rostock Medical Center, Schillingallee 35, 18057 Rostock, Germany.ORCID 0000-0002-3189-0849
Stephan Albrecht EnderDepartment of Orthopaedics and Orthopaedic Surgery, University Medicine Greifswald, Ferdinand-Sauerbruch Straße, 17475 Greifswald, Germany.
Benjamin UlmarDepartment of Trauma, Hand and Reconstructive Surgery, University of Rostock Medical Center, Schillingallee 35, 18057 Rostock, Germany.
Philipp HerlynDepartment of Trauma, Hand and Reconstructive Surgery, University of Rostock Medical Center, Schillingallee 35, 18057 Rostock, Germany.ORCID 0000-0001-7174-1429
Thomas MittlmeierDepartment of Trauma, Hand and Reconstructive Surgery, University of Rostock Medical Center, Schillingallee 35, 18057 Rostock, Germany.ORCID 0000-0002-0536-8045
Georg GradlDepartment of Trauma, Orthopedic and Reconstructive Surgery, Klinikum München Harlaching, Sanatoriumsplatz 2, 81545 München, Germany.
University of Rostock · DEMünchen Klinik Harlaching · DEUniversitätsmedizin Greifswald · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionVertebral compression fractures (VCFs) affect 20% of people over the age of 70 with increasing incidence. Kypho-/vertebroplasty as standard operative procedures are associated with limitations like cement leakage, limited reduction capabilities, and risk for adjacent fractures. To address these shortcomings, we introduce a new minimal invasive cementless VCF fixation technique.

methodsFour patients (72.3 years, range 70-76) with VCFs type AO/Müller A1.3 and concomitant osteoporosis were treated by minimal invasive transpedicular placement of two intervertebral mesh cages for fracture reduction and maintenance. Follow-up included functional/radiological assessment and clinical scores and averaged 27.7 months (24-28).

resultsEndplate reduction was achieved in all cases (mean surgery time: 28.5 minutes). Kyphotic (KA) and Cobb angle revealed considerable improvements postoperatively (KA 14.5° to 10.7°/Cobb 10.1° to 8.3°). Slight loss of vertebral reduction (KA: 12.6°) and segment rekyphosis (Cobb: 10.7°) were observed for final follow-up. Pain improved from 8.8 to 2.8 (visual analogue scale). All cases showed signs of bony healing. No perioperative complications and no adjacent fractures occurred.

conclusionPreliminary results in a small, selected patient collective indicate the ability of bony healing for osteoporotic VCFs. Cementless fixation using intravertebral titanium mesh cages revealed substantial pain relief, adequate reduction, and reduction maintenance without complications. Trial registration number is DRKS00005657, German Clinical Trials Register (DKRS).

Indexed as

Fracture FixationAgedBone CementsFemaleFractures, CompressionHumansMaleOsteoporosisPain MeasurementProstheses and ImplantsRadiographySpinal FracturesTitaniumBone CementsTitanium