Evidence map›Paper›PMID 25107387›Full record

ReviewThe American journal of medicine2015

Ambulatory blood pressure monitoring in clinical practice: a review.

J Rick Turner, Anthony J Viera, Daichi Shimbo

2 registry-linked trialsOpen access · greenAbstract readReview
In one paragraph

Review in The American journal of medicine, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 52 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
52citing papers in PubMed, 2 pooled it
5.3field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03147573 nacompletednot on this mapstarted 2017, after this paper: background citation

Validity of 1-hour Blood Pressure Monitoring Against the Usual Methods for Diagnosis of Hypertension

TypeinterventionalSponsorConsorci d'Atenció Primària de Salut de l'EixampleRan2017 to 2019Enrolled500ConditionsHypertensionArms1-hour blood pressure monitoring (1BPM), 24-hour ambulatory blood pressure monitoring (ABPM), Office blood pressure measurement (OBPM), Home blood pressure monitoring (HBPM)
NCT07396857 narecruitingnot on this mapstarted 2025, after this paper: background citation

The Role of Endothelial-Derived Hyperpolarization Factors on 24-hr Blood Pressure Regulation Following a Bout of Prolonged Sitting

TypeinterventionalSponsorUniversité de SherbrookeRan2025 to 2026Enrolled40ConditionsCardiovascularArmsPlacebo, Fluconazole 150 mg
3 · Its place in the literature

Who cites it

52 citing papers in PubMed, 2 syntheses or guidelines pooled it, 121 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Trial
  4. Trial
  5. Trial
  6. Trial
  7. Polymer-Based Multiparameter Sensing Integrated Photonic Chip for Health Monitoring.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Article
  8. Observational
  9. Article
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Review
  19. Social Support: The Effect on Nocturnal Blood Pressure Dipping.International journal of environmental research and public health · 2023
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 3 institutions in 1 country.

J Rick TurnerQuintiles, Durham, NC. Electronic address: rick.turner@quintiles.com.
Anthony J VieraUniversity of North Carolina at Chapel Hill School of Medicine, Chapel Hill.
Daichi ShimboColumbia University Medical Center, New York, NY.
Columbia University Irving Medical Center · USIQVIA (United States) · USUniversity of North Carolina at Chapel Hill · US

Funding

WORKSITE BLOOD PRESSURE STUDYP01HL047540 · NHLBI · WEILL MEDICAL COLLEGE OF CORNELL UNIV · PI SCHWARTZ, JOSEPH E · 1993 to 2014
$27.7M
Reproducibility and Clinical Implications of Masked HypertensionR01HL098604 · NHLBI · UNIV OF NORTH CAROLINA CHAPEL HILL · PI VIERA, ANTHONY J · 2010 to 2012
$1.9M
NHLBI NIH HHS P01 HL047540NHLBI NIH HHS R01 HL098604
6 · The paper itself

Abstract

Ambulatory blood pressure monitoring offers the ability to collect blood pressure readings several times an hour across a 24-hour period. Ambulatory blood pressure monitoring facilitates the identification of white-coat hypertension, the phenomenon whereby certain individuals who are not taking antihypertensive medication show elevated blood pressure in a clinical setting but show nonelevated blood pressure averages when assessed by ambulatory blood pressure monitoring. In addition, readings can be segmented into time windows of particular interest, for example, mean daytime and nighttime values. During sleep, blood pressure typically decreases, or dips, such that mean sleep blood pressure is lower than mean awake blood pressure. A nondipping pattern and nocturnal hypertension are strongly associated with increased cardiovascular morbidity and mortality. Approximately 70% of individuals have blood pressure dips of ≥10% at night, whereas 30% have nondipping patterns, when blood pressure remains similar to daytime average or occasionally increases above daytime average. The various blood pressure categorizations afforded by ambulatory blood pressure monitoring are valuable for clinical management of high blood pressure because they increase the accuracy for diagnosis and the prediction of cardiovascular risk.

Indexed as

Blood Pressure Monitoring, AmbulatoryBlood PressureHumansHypertensionAmbulatory blood pressure monitoringHigh blood pressureMasked hypertensionNocturnal blood pressureWhite-coat hypertension

Identifiers

PMID25107387
PMCPMC4877527
OpenAlexW1984125872

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.