ArticleThe Analyst2014
Microfluidic device with tunable post arrays and integrated electrodes for studying cellular release.
Article in The Analyst, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 16 citations in OpenAlex.
- 3D-Printed Microfluidic-Based Cell Culture System With Analysis to Investigate Macrophage Activation.Electrophoresis · 2025Article
- PolyJet Three-dimensional-Printed Microchip Devices With Integrated Carbon Electrodes for Neurotransmitter Analysis.Journal of separation science · 2025Article
- Adoption of microfluidic MEA technology for electrophysiology of 3D neuronal networks exposed to suborbital conditions.NPJ microgravity · 2025Article
- A 3D-printed, multi-modal microfluidic device for measuring nitric oxide and ATP release from flowing red blood cells.Analytical methods : advancing methods and applications · 2022Article
- Red blood cells in type 1 diabetes and multiple sclerosis and technologies to measure their emerging roles.Journal of translational autoimmunity · 2022Review
- Instrumented Microphysiological Systems for Real-Time Measurement and Manipulation of Cellular Electrochemical Processes.iScience · 2019Review
- Microfluidic device using a gold pillar array and integrated electrodes for on-chip endothelial cell immobilization, direct RBC contact, and amperometric detection of nitric oxide.Electroanalysis · 2019Article
- Insert-based microfluidics for 3D cell culture with analysis.Analytical and bioanalytical chemistry · 2018Article
- Article
- Integrated Electrodes and Electrospray Emitter for Polymer Microfluidic Nanospray-MS Interface.Analytical methods : advancing methods and applications · 2016Article
- Microfluidic Organ/Body-on-a-Chip Devices at the Convergence of Biology and Microengineering.Sensors (Basel, Switzerland) · 2015Review
- Fabrication and Characterization of All-Polystyrene Microfluidic Devices with Integrated Electrodes and Tubing.Analytical methods : advancing methods and applications · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
Abstract
In this paper, we describe the development of a planar, pillar array device that can be used to image either side of a tunable membrane, as well as sample and detect small molecules in a cell-free region of the microchip. The pores are created by sealing two parallel PDMS microchannels (a cell channel and a collector channel) over a gold pillar array (5 or 10 μm in height), with the device being characterized and optimized for small molecule cross-over while excluding a flowing cell line (here, red blood cells, RBCs). The device was characterized in terms of the flow rate dependence of analyte cross-over and cell exclusion as well as the ability to perform amperometric detection of catechol and nitric oxide (NO) as they cross-over into the collector channel. Using catechol as the test analyte, the limits of detection (LOD) of the cross-over for the 10 μm and 5 μm pillar array heights were shown to be 50 nM and 105 nM, respectively. Detection of NO was made possible with a glassy carbon detection electrode (housed in the collector channel) modified with Pt-black and Nafion, to enhance sensitivity and selectivity, respectively. Reproducible cross-over of NO as a function of concentration resulted in a linear correlation (r(2) = 0.995, 7.6-190 μM), with an LOD for NO of 230 nM on the glassy carbon/Pt-black/0.05% Nafion electrode. The applicability of the device was demonstrated by measuring the NO released from hypoxic RBCs, with the device allowing the released NO to cross-over into a cell free channel where it was detected in close to real-time. This type of device is an attractive alternative to the use of 3-dimensional devices with polycarbonate membranes, as either side of the membrane can be imaged and facile integration of electrochemical detection is possible.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.