Evidence map›Paper›PMID 25104291›Full record

ArticleAJNR. American journal of neuroradiology2014

Detection of carotid artery stenosis: a comparison between 2 unenhanced MRAs and dual-source CTA.

P Lv, J Lin, D Guo, H Liu, X Tang, C Fu, J Hu

Open access · hybridAbstract readComparative Study
In one paragraph

Article in AJNR. American journal of neuroradiology, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed, 1 pooled it
1.7field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 1 synthesis or guideline pooled it, 18 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Review
  9. Article
  10. Review
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

P LvFrom the Department of Radiology (P.L., J.L., H.L.), Zhongshan Hospital, Shanghai Medical College of Fudan University and Shanghai Institute of Medical Imaging, Shanghai, China.
J LinFrom the Department of Radiology (P.L., J.L., H.L.), Zhongshan Hospital, Shanghai Medical College of Fudan University and Shanghai Institute of Medical Imaging, Shanghai, China lin.jiang@zs-hospital.sh.cn guo.daqiao@zs-hospital.sh.cn.
D GuoDepartment of Vascular Surgery (D.G., X.T.), Zhongshan Hospital, Fudan University and Institute of Vascular Surgery, Shanghai, China lin.jiang@zs-hospital.sh.cn guo.daqiao@zs-hospital.sh.cn.
H LiuFrom the Department of Radiology (P.L., J.L., H.L.), Zhongshan Hospital, Shanghai Medical College of Fudan University and Shanghai Institute of Medical Imaging, Shanghai, China.
X TangDepartment of Vascular Surgery (D.G., X.T.), Zhongshan Hospital, Fudan University and Institute of Vascular Surgery, Shanghai, China.
C FuSiemens Shenzhen Magnetic Resonance (C.F.), Shenzhen, China.
J HuDepartment of Cardiology (J.H.), Zhongshan Hospital, Fudan University, Shanghai, China.
Fudan University · CNShanghai Medical College of Fudan University · CNSiemens (China) · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeDual-source CTA and black-blood MRA are recently developed techniques for evaluating carotid stenosis. The purpose of this study was to compare dual-source CTA with black-blood MRA and conventional TOF MRA in both detecting carotid stenosis by using DSA as a reference standard and demonstrating plaque morphology. MATERIALS AND

methodsThirty patients with suspected carotid artery stenosis underwent unenhanced MRA by using black-blood and TOF MRA and dual-source CTA. Source images from unenhanced MRAs and dual-source CTA were reconstructed with MIP or curved planar reconstruction. The degree of carotid artery stenosis was measured, and plaque surface morphology at the stenosis was analyzed and compared among different techniques.

resultsGood correlation was observed for measuring the degree of carotid stenosis among dual-source CTA, black-blood MRA, TOF MRA, and DSA. Sensitivity and specificity for detecting severe stenosis were 100% and 97% with dual-source CTA, 100% and 95% with black-blood MRA, and 79% and 95% with TOF MRA. None of the 3 technologies resulted in stenosis of <50% being overestimated. Plaque surface irregularity or ulceration was more frequently detected with dual-source CTA and black-blood MRA than with TOF MRA and DSA.

conclusionsThis preliminary study shows that black-blood MRA is a promising technique, comparable with dual-source CTA and DSA, but better than TOF MRA, in the evaluation of carotid stenosis. Unlike dual-source CTA, black-blood MRA requires no intravenous contrast or radiation.

Indexed as

Angiography, Digital SubtractionAgedCarotid StenosisFemaleHumansImage Processing, Computer-AssistedMagnetic Resonance AngiographyMaleMiddle AgedSensitivity and SpecificityTomography, X-Ray Computed

Identifiers

PMID25104291
PMCPMC7965318
OpenAlexW1970945502

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.