Evidence map›Paper›PMID 25093630›Full record

ArticleMagnetic resonance imaging2014

Rapid acquisition strategy for functional T1ρ mapping of the brain.

Casey P Johnson, Hye-Young Heo, Daniel R Thedens, John A Wemmie, Vincent A Magnotta

Abstract read
In one paragraph

Article in Magnetic resonance imaging, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.8field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Comparison of TThe Journal of neuropsychiatry and clinical neurosciences · 2020
    Article
  3. Review
  4. Article
  5. Article
  6. Eccentricity mapping of the human visual cortex to evaluate temporal dynamics of functional T1ρ mapping.Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism · 2015
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Casey P JohnsonDepartment of Radiology, University of Iowa, Iowa City, IA. Electronic address: mricpj@gmail.com.
Hye-Young HeoDepartment of Biomedical Engineering, University of Iowa, Iowa City, IA.
Daniel R ThedensDepartment of Radiology, University of Iowa, Iowa City, IA.
John A WemmieDepartment of Psychiatry, University of Iowa, Iowa City, IA; Department of Veterans Affairs Medical Center, Iowa City, IA.
Vincent A MagnottaDepartment of Radiology, University of Iowa, Iowa City, IA; Department of Biomedical Engineering, University of Iowa, Iowa City, IA; Department of Psychiatry, University of Iowa, Iowa City, IA.
University of Iowa · US

Funding

Regulation of Cerebral Blood Flow by Acid-Sensing Ion Channels (ASICs)R01HL113863 · NHLBI · UNIVERSITY OF IOWA · PI FARACI, FRANK M, WEMMIE, JOHN A · 2012 to 2016
$1.9M
Modeling CO2-evoked fear in mice: role of acid-sensing ion channelsR01MH085724 · NIMH · UNIVERSITY OF IOWA · PI WEMMIE, JOHN A · 2009 to 2013
$1.8M
Brain pH and Acid Sensing in Depression-Related BehaviorI01BX000741 · VA · IOWA CITY VA MEDICAL CENTER · PI WEMMIE, JOHN A · 2011 to 2018
–
BLRD VA I01 BX000741NHLBI NIH HHS 5R01HL113863-01NHLBI NIH HHS R01 HL113863NIMH NIH HHS 1R01MH085724-01NIMH NIH HHS R01 MH085724
6 · The paper itself

Abstract

Functional T1ρ mapping has been proposed as a method to assess pH and metabolism dynamics in the brain with high spatial and temporal resolution. The purpose of this work is to describe and evaluate a variant of the spin-locked echo-planar imaging sequence for functional T1ρ mapping at 3T. The proposed sequence rapidly acquires a time series of T1ρ maps with 4.0second temporal resolution and 10 slices of volumetric coverage. Simulation, phantom, and in vivo experiments are used to evaluate many aspects of the sequence and its implementation including fidelity of measured T1ρ dynamics, potential confounds to the T1ρ response, imaging parameter tradeoffs, time series analysis approaches, and differences compared to blood oxygen level dependent functional magnetic resonance imaging. It is shown that the high temporal resolution and volumetric coverage of the sequence are obtained with some expense including underestimation of the T1ρ response, sensitivity to T1 dynamics, and reduced signal-to-noise ratio. In vivo studies using a flashing checkerboard functional magnetic resonance imaging paradigm suggest differences between T1ρ and blood oxygen level dependent activation patterns. Possible sources of the functional T1ρ response and potential sequence improvements are discussed. The capability of T1ρ to map whole-brain pH and metabolism dynamics with high temporal and spatial resolution is potentially unique and warrants further investigation and development.

Indexed as

AdultBrainBrain MappingEcho-Planar ImagingHumansImage Processing, Computer-AssistedMagnetic Resonance ImagingMalePhantoms, ImagingBOLDDynamicsfMRIMetabolismpHT1rho

Identifiers

PMID25093630
PMCPMC4171198
OpenAlexW2113553930

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.