Evidence map›Paper›PMID 25089975›Full record

ArticleApplied optics2014

Motion artifact and background noise suppression on optical microangiography frames using a naïve Bayes mask.

Roberto Reif, Utku Baran, Ruikang K Wang

Open access · greenAbstract read
In one paragraph

Article in Applied optics, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.9field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Roberto Reif
Utku Baran
Ruikang K Wang
University of Washington · US

Funding

OPTICAL MICROANGIOGRAHY OF CEREBROVASCULAR PERFUSIONR01HL093140 · NHLBI · UNIVERSITY OF WASHINGTON · PI WANG, RUIKANG · 2008 to 2017
$4.2M
Volumetric imaging of blood perfusion and tissue morphology in the cochleaR01DC010201 · NIDCD · UNIVERSITY OF WASHINGTON · PI WANG, RUIKANG · 2009 to 2013
$2.2M
Label-free optical imaging of 3D structural and functional microcirculationsR01EB009682 · NIBIB · UNIVERSITY OF WASHINGTON · PI WANG, RUIKANG · 2009 to 2012
$1.7M
NHLBI NIH HHS R01 HL093140NHLBI NIH HHS R01HL093140NIBIB NIH HHS R01 EB009682NIBIB NIH HHS R01EB009682NIDCD NIH HHS R01 DC010201NIDCD NIH HHS R01DC010201
6 · The paper itself

Abstract

Optical coherence tomography (OCT) is a technique that allows for the three-dimensional (3D) imaging of small volumes of tissue (a few millimeters) with high resolution (∼10  μm). Optical microangiography (OMAG) is a method of processing OCT data, which allows for the extraction of the tissue vasculature with capillary resolution from the OCT images. Cross-sectional B-frame OMAG images present the location of the patent blood vessels; however, the signal-to-noise-ratio of these images can be affected by several factors such as the quality of the OCT system and the tissue motion artifact. This background noise can appear in the en face projection view image. In this work we propose to develop a binary mask that can be applied on the cross-sectional B-frame OMAG images, which will reduce the background noise while leaving the signal from the blood vessels intact. The mask is created by using a naïve Bayes (NB) classification algorithm trained with a gold standard image which is manually segmented by an expert. The masked OMAG images present better contrast for binarizing the image and quantifying the result without the influence of noise. The results are compared with a previously developed frequency rejection filter (FRF) method which is applied on the en face projection view image. It is demonstrated that both the NB and FRF methods provide similar vessel length fractions. The advantage of the NB method is that the results are applicable in 3D and that its use is not limited to periodic motion artifacts.

Indexed as

AlgorithmsArtifactsArtificial IntelligenceAngiographyImage EnhancementImage Interpretation, Computer-AssistedMotionReproducibility of ResultsSensitivity and SpecificitySignal-To-Noise RatioTomography, Optical Coherence

Identifiers

PMID25089975
PMCPMC4303031
OpenAlexW1969667096

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.