ArticleMedical physics2014
Task-based detectability in CT image reconstruction by filtered backprojection and penalized likelihood estimation.
Article in Medical physics, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 49 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
49 citing papers in PubMed.
- Quality control for digital tomosynthesis in the ECOG-ACRIN EA1151 TMIST trial.Medical physics · 2023Trial
- Evaluation of deep-learning iterative reconstruction combined with high-frequency kernels in CT: a task-based image quality study.European radiology experimental · 2026Article
- Task-based evaluation of axial and multiplanar reconstructions in computed tomography: A volumetric analysis of spatial resolution, noise, and detectability.Journal of applied clinical medical physics · 2026Article
- Optimization of hypovascular liver lesion detectability in dual-energy CT using deep learning image reconstruction: a phantom study for potential iodine dose reduction.European radiology experimental · 2026Article
- Resolution-noise characteristics of common FDK filter kernels: A practical reference for preclinical cone-beam micro-CT.PloS one · 2026Article
- Deep learning CT image restoration using system blur and noise models.Journal of medical imaging (Bellingham, Wash.) · 2025Article
- Experimental measurement of local noise power spectrum (NPS) in photon counting detector-CT (PCD-CT) using a single data acquisition.Medical physics · 2024Article
- End-to-end Deep Learning Restoration of GLCM Features from blurred and noisy images.Proceedings of SPIE--the International Society for Optical Engineering · 2024Article
- Fourier Diffusion for Sparse CT Reconstruction.Proceedings of SPIE--the International Society for Optical Engineering · 2024Article
- Accurate and efficient measurement of channelized Hotelling observer-based low-contrast detectability on the ACR CT accreditation phantom.Medical physics · 2023Article
- Deep Learning CT Image Restoration using System Blur Models.Proceedings of SPIE--the International Society for Optical Engineering · 2023Article
- A signal detection model for quantifying overregularization in nonlinear image reconstruction.Medical physics · 2021Article
- Standardization of histogram- and gray-level co-occurrence matrices-based radiomics in the presence of blur and noise.Physics in medicine and biology · 2021Article
- End-to-end Modeling for Predicting and Estimating Radiomics: Application to Gray Level Co-occurrence Matrices in CT.Proceedings of SPIE--the International Society for Optical Engineering · 2021Article
- A learning-based method for online adjustment of C-arm Cone-beam CT source trajectories for artifact avoidance.International journal of computer assisted radiology and surgery · 2020Article
- Frequency-dependent signal and noise in spectroscopic x-ray imaging.Medical physics · 2020Article
- Blind deconvolution in model-based iterative reconstruction for CT using a normalized sparsity measure.Physics in medicine and biology · 2019Article
- Objective assessment of task performance: a comparison of two FFDM detectors using an anthropomorphic breast phantom.Journal of medical imaging (Bellingham, Wash.) · 2019Article
- Known-component 3D image reconstruction for improved intraoperative imaging in spine surgery: A clinical pilot study.Medical physics · 2019Article
- Convergence criterion for MBIR based on the local noise-power spectrum: Theory and implementation in a framework for accelerated 3D image reconstruction with a morphological pyramid.Proceedings of SPIE--the International Society for Optical Engineering · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
purposeNonstationarity is an important aspect of imaging performance in CT and cone-beam CT (CBCT), especially for systems employing iterative reconstruction. This work presents a theoretical framework for both filtered-backprojection (FBP) and penalized-likelihood (PL) reconstruction that includes explicit descriptions of nonstationary noise, spatial resolution, and task-based detectability index. Potential utility of the model was demonstrated in the optimal selection of regularization parameters in PL reconstruction.
methodsAnalytical models for local modulation transfer function (MTF) and noise-power spectrum (NPS) were investigated for both FBP and PL reconstruction, including explicit dependence on the object and spatial location. For FBP, a cascaded systems analysis framework was adapted to account for nonstationarity by separately calculating fluence and system gains for each ray passing through any given voxel. For PL, the point-spread function and covariance were derived using the implicit function theorem and first-order Taylor expansion according to Fessler ["Mean and variance of implicitly defined biased estimators (such as penalized maximum likelihood): Applications to tomography," IEEE Trans. Image Process. 5(3), 493-506 (1996)]. Detectability index was calculated for a variety of simple tasks. The model for PL was used in selecting the regularization strength parameter to optimize task-based performance, with both a constant and a spatially varying regularization map.
resultsTheoretical models of FBP and PL were validated in 2D simulated fan-beam data and found to yield accurate predictions of local MTF and NPS as a function of the object and the spatial location. The NPS for both FBP and PL exhibit similar anisotropic nature depending on the pathlength (and therefore, the object and spatial location within the object) traversed by each ray, with the PL NPS experiencing greater smoothing along directions with higher noise. The MTF of FBP is isotropic and independent of location to a first order approximation, whereas the MTF of PL is anisotropic in a manner complementary to the NPS. Task-based detectability demonstrates dependence on the task, object, spatial location, and smoothing parameters. A spatially varying regularization "map" designed from locally optimal regularization can improve overall detectability beyond that achievable with the commonly used constant regularization parameter.
conclusionsAnalytical models for task-based FBP and PL reconstruction are predictive of nonstationary noise and resolution characteristics, providing a valuable framework for understanding and optimizing system performance in CT and CBCT.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials