Trial reportJournal of diabetes science and technology2014
Accuracy of a new patch pump based on a microelectromechanical system (MEMS) compared to other commercially available insulin pumps: results of the first in vitro and in vivo studies.
Trial report in Journal of diabetes science and technology, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed.
- Performance and patients' satisfaction with the A7+TouchCare insulin patch pump system: A randomized controlled non-inferiority study.PloS one · 2023Trial
- Smart closed-loop drug delivery systems.Nature reviews bioengineering · 2025Article
- Adherence Definitions, Measurement Modalities, and Psychometric Properties in HIV, Diabetes, and Nutritional Supplementation Studies: A Scoping Review.Patient preference and adherence · 2025Review
- Bench-Side Dose Accuracy of an Open-Source Ultra-Low-Cost Insulin-Pump, With Testing Conducted to IEC 60601-2-24.Journal of diabetes science and technology · 2024Article
- Low-cost, low-power, clockwork syringe pump.HardwareX · 2023Article
- Reporting Insulin Pump Accuracy: Trumpet Curves According to IEC 60601-2-24 and Beyond.Journal of diabetes science and technology · 2019Article
- Accuracy of Bolus and Basal Rate Delivery of Different Insulin Pump Systems.Diabetes technology & therapeutics · 2019Article
- Patch Pumps: Are They All the Same?Journal of diabetes science and technology · 2019Review
- Establishing Methods to Determine Clinically Relevant Bolus and Basal Rate Delivery Accuracy of Insulin Pumps.Journal of diabetes science and technology · 2019Article
- Occlusion Detection Time in Insulin Pumps at Two Different Basal Rates.Journal of diabetes science and technology · 2018Article
- 10th Annual Symposium on Self-Monitoring of Blood Glucose, April 27-29, 2017, Warsaw, Poland.Diabetes technology & therapeutics · 2018Article
- Insulin Pump Occlusions: For Patients Who Have Been Around the (Infusion) Block.Journal of diabetes science and technology · 2017Article
- Boluses in Insulin Therapy.Journal of diabetes science and technology · 2017Review
- A Comparative Pulse Accuracy Study of Two Commercially Available Patch Insulin Infusion Pumps.European endocrinology · 2016Article
- Artificial Pancreas Device Systems for the Closed-Loop Control of Type 1 Diabetes: What Systems Are in Development?Journal of diabetes science and technology · 2016Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The JewelPUMP™ (JP) is a new patch pump based on a microelectromechanical system that operates without any plunger. The study aimed to evaluate the infusion accuracy of the JP in vitro and in vivo. For the in vitro studies, commercially available pumps meeting the ISO standard were compared to the JP: the MiniMed® Paradigm® 712 (MP), Accu-Chek® Combo (AC), OmniPod® (OP), Animas® Vibe™ (AN). Pump accuracy was measured over 24 hours using a continuous microweighing method, at 0.1 and 1 IU/h basal rates. The occlusion alarm threshold was measured after a catheter occlusion. The JP, filled with physiological serum, was then tested in 13 patients with type 1 diabetes simultaneously with their own pump for 2 days. The weight difference was used to calculate the infused insulin volume. The JP showed reduced absolute median error rate in vitro over a 15-minute observation window compared to other pumps (1 IU/h): ±1.02% (JP) vs ±1.60% (AN), ±1.66% (AC), ±2.22% (MP), and ±4.63% (OP), P < .0001. But there was no difference over 24 hours. At 0.5 IU/h, the JP was able to detect an occlusion earlier than other pumps: 21 (19; 25) minutes vs 90 (85; 95), 58 (42; 74), and 143 (132; 218) minutes (AN, AC, MP), P < .05 vs AN and MP. In patients, the 24-hour flow error was not significantly different between the JP and usual pumps (-2.2 ± 5.6% vs -0.37 ± 4.0%, P = .25). The JP was found to be easier to wear than conventional pumps. The JP is more precise over a short time period, more sensitive to catheter occlusion, well accepted by patients, and consequently, of potential interest for a closed-loop insulin delivery system.