Evidence map›Paper›PMID 25071970›Full record

ArticleBiomedical optics express2014

Quantifying tissue mechanical properties using photoplethysmography.

Tony J Akl, Mark A Wilson, M Nance Ericson, Gerard L Coté

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
0.6field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it, 20 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Tony J AklDepartment of Biomedical Engineering, Texas A&M University, 5045 Emerging Technologies Building, 3120 TAMU, College Station, TX 77843-3120, USA.
Mark A WilsonDepartment of Surgery, University of Pittsburgh, 200 Lothrop Street, Pittsburgh, PA 15213 USA ; VA Pittsburgh Healthcare System, University Dr. C-1w142, Pittsburgh, PA 15240 USA.
M Nance EricsonOak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, TN 37831-6006 USA.
Gerard L CotéDepartment of Biomedical Engineering, Texas A&M University, 5045 Emerging Technologies Building, 3120 TAMU, College Station, TX 77843-3120, USA.
Texas A&M University · USOak Ridge National Laboratory · US

Funding

Implantable Sensor for Transplant Tissue MonitoringR01GM077150 · NIGMS · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI WILSON, MARK A. · 2007 to 2011
$2.7M
NIGMS NIH HHS R01 GM077150
6 · The paper itself

Abstract

Photoplethysmography (PPG) is a non-invasive optical method that can be used to detect blood volume changes in the microvascular bed of tissue. The PPG signal comprises two components; a pulsatile waveform (AC) attributed to changes in the interrogated blood volume with each heartbeat, and a slowly varying baseline (DC) combining low frequency fluctuations mainly due to respiration and sympathetic nervous system activity. In this report, we investigate the AC pulsatile waveform of the PPG pulse for ultimate use in extracting information regarding the biomechanical properties of tissue and vasculature. By analyzing the rise time of the pulse in the diastole period, we show that PPG is capable of measuring changes in the Young's Modulus of tissue mimicking phantoms with a resolution of 4 KPa in the range of 12 to 61 KPa. In addition, the shape of the pulse can potentially be used to diagnose vascular complications by differentiating upstream from downstream complications. A Windkessel model was used to model changes in the biomechanical properties of the circulation and to test the proposed concept. The modeling data confirmed the response seen in vitro and showed the same trends in the PPG rise and fall times with changes in compliance and vascular resistance.

Indexed as

(170.3660) Light propagation in tissues(280.1415) Biological sensing and sensors

Identifiers

PMID25071970
PMCPMC4102370
OpenAlexW2067862553

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked