ArticleStrahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al]2014
New possibilities for volumetric-modulated arc therapy using the Agility™ 160-leaf multileaf collimator.
Article in Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al], 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- A Comparative Analysis of Peripheral Dose Measurement Between Apex and Agility Collimators in Linear Accelerators.Asian Pacific journal of cancer prevention : APJCP · 2026Article
- Dosimetric comparison of VMAT plans in preoperative short-course rectal radiotherapy.Scientific reports · 2024Article
- Dosimetric evaluation study of IMRT and VMAT techniques for prostate cancer based on different multileaf collimator designs.Radiation and environmental biophysics · 2023Article
- Challenges in modeling the Agility multileaf collimator in treatment planning systems and current needs for improvement.Medical physics · 2022Article
- Effect of dental metal artifact conversion volume on dose distribution in head-and-neck volumetric-modulated arc therapy.Journal of applied clinical medical physics · 2020Article
- Dynamic positioning accuracy of a novel multileaf collimator for volumetric modulated arc therapy.Radiological physics and technology · 2016Article
- Monte Carlo Modeling of the Agility MLC for IMRT and VMAT Calculations.In vivo (Athens, Greece)Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThis study compares the quality of intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) plans optimized for an Elekta Agility(TM) (Elekta, Stockholm, Sweden) multileaf collimator (MLC; leaf width 5 mm) and an Elekta MLCi2 (leaf width 10 mm) for complex target volumes (anal, AC; head and neck, H&N and prostate cancer, PC). PATIENTS AND
methodsFor plan comparisons, 15 patients who had been treated with IMRT or VMAT using the MLCi2 were selected. For each patient, a retrospective treatment plan using the MLCi2 for the technique not applied was created, as were treatment plans for both techniques using the Agility(TM) MLC. Dose-volume histograms (DHVs) for planning target volumes (PTVs) and organs at risk (OARs) were compared. Further parameters relating to dose conformity, dose homogeneity and mean dose (Dmean) to the PTV, compliance with the intended OAR dose criteria and overall dose to normal tissue were analyzed. Verification measurements were performed and optimization and treatment times were compared.
resultsCompared to the MLCi2 plans, the Agility(TM) IMRT and VMAT plans show better or equivalent results in terms of PTV dose conformity and homogeneity. Compliance with the intended OAR dose criteria does not differ according to technique or MLC type. Slight differences are shown for dose distributions in OARs and normal tissue. Verification measurements show that all plans fulfill the acceptance criteria of a minimum of 95 % matched dose points for the 3 %/3 mm γ criterion. Optimization times for the VMAT plans increase compared to the IMRT plans, whereas treatment times decrease.
conclusionWith the MLCi2, treatment of complex target volumes with VMAT was only possible with compromises in terms of target coverage. Using the Agility(TM) MLC, even complex target volumes can be treated with VMAT without compromising target coverage or resulting in higher exposure of OARs or normal tissue.