Evidence map›Paper›PMID 25059851›Full record

Trial reportClinical orthopaedics and related research2014

Does advanced cryotherapy reduce pain and narcotic consumption after knee arthroplasty?

Emmanuel Thienpont

3 registry-linked trialsAbstract readComparative StudyRandomized Controlled Trial
In one paragraph

Trial report in Clinical orthopaedics and related research, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 3 registered trials, which are not on this map. Cited by 27 papers, 8 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
27citing papers in PubMed, 8 pooled it
4.1field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05572359 nacompletednot on this mapstarted 2023, after this paper: background citation

Effect of Cryo- and Compression Therapy After Total Knee and Unicompartmental Arthroplasty, A Randomised Controlled Trial

TypeinterventionalSponsorMartini Hospital GroningenRan2023 to 2026Enrolled208ConditionsOsteo Arthritis KneeArmscryo-and compression brace
NCT06673277 nacompletednot on this mapstarted 2025, after this paper: background citation

Skin Temperature Response to Prolonged Cooling With an Electronic Continuous Cold-flow Cryocompression Device: a Safety and Feasibility Pilot

TypeinterventionalSponsorUniversity of WinchesterRan2025 to 2025Enrolled16ConditionsSkin Temperature Change, Adverse Effects, Safety of Intervention, CryotherapyArmsProlonged (2-hour) cryocompression therapy
NCT07134283 nacompletednot on this mapstarted 2024, after this paper: background citation

The Effect of Preoperatively Initiated Cold Application on Postoperative Bleeding, Pain, and Functional Status in Total Knee Arthroplasty

TypeinterventionalSponsorAnkara City Hospital BilkentRan2024 to 2025Enrolled208ConditionsKnee Osteoarthritis, Total Knee Arthroplasty, Cryotherapy, Postoperative Pain ManagementArmsPreoperative and Postoperative Cold Therapy with Gel Cold Pack, Postoperative Cold Therapy with Gel Cold Pack
3 · Its place in the literature

Who cites it

27 citing papers in PubMed, 8 syntheses or guidelines pooled it, 80 citations in OpenAlex.

  1. Guideline
  2. Pooled it
  3. Pooled it
  4. Pooled it
  5. Cryotherapy following total knee replacement.The Cochrane database of systematic reviews · 2023
    Pooled it
  6. Pooled it
  7. Guideline
  8. Pooled it
  9. Trial
  10. Trial
  11. Trial
  12. Trial
  13. Reduced opiate use after total knee arthroplasty using computer-assisted cryotherapy.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2019
    Trial
  14. Trial
  15. Article
  16. Article
  17. Article
  18. Is medial pivot total knee arthroplasty suitable for patients with valgus knee osteoarthritis?European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2022
    Article
  19. Review
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

1 author at 1 institution in 1 country.

Emmanuel ThienpontCliniques Universitaires Saint Luc-UCL, Avenue Hippocrate 10, 1200, Brussels, Belgium, emmanuel.thienpont@uclouvain.be.
Cliniques Universitaires Saint-Luc · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCryotherapy has been used to enhance recovery after orthopaedic surgery. Several cooling devices are available but few can guarantee a fixed temperature during a prolonged time and therefore have been criticized. The arrival of new advanced cryotherapy devices made it possible to test the effect of prolonged cooling on rehabilitation after joint replacement. QUESTIONS/PURPOSES: The hypotheses of this randomized controlled trial (RCT) were that advanced cryotherapy devices compared with cold packs result in (1) better postoperative pain control resulting in a lower consumption of narcotics; (2) better early ROM; and (3) less postoperative bleeding and swelling.

methodsA priori sample size calculation had determined that to detect a difference of 2 points on the VAS, a sample size of 50 subjects per group at followup would be required, given a study power of 80%. One hundred sixteen patients were included and randomly allocated to receive advanced cryotherapy (n=58) or use of cold packs (n=58). The primary outcomes for the study were to evaluate pain with the VAS and analgesics consumption. Secondary outcomes were postoperative ROM, swelling, and blood loss. One hundred (50 in each group) patients had complete data available for analysis.

resultsNo statistically significant differences in VAS, need for analgesics, nor in secondary outcomes were observed, except for substantially reduced flexion at 6 weeks in the advanced cryotherapy group (114° versus 120°).

conclusionsAdvanced cryotherapy with a continuous temperature for a prolonged period does not deliver expected results of superior early recovery after knee arthroplasty. Greater sample sizes are required to fully determine significant differences between the two techniques for these study parameters. Immobilization of the knee in extension during the prolonged cryotherapy session resulted in lower active flexion at 6 weeks after surgery for the advanced cryotherapy group. Advanced cryotherapy should not be used in fast track knee arthroplasty if the economic cost is higher than the price of cold packs or offers no other concomitant advantages. LEVEL OF EVIDENCE: Level II, therapeutic study. See the Instructions for Authors for a complete description of levels of evidence.

Indexed as

AgedAnalgesicsArthroplasty, Replacement, KneeCryotherapyEdemaFemaleHumansKnee JointMaleNarcoticsPain MeasurementPostoperative HemorrhagePostoperative PainRange of Motion, ArticularRecovery of FunctionTreatment OutcomeAnalgesicsNarcotics

Identifiers

PMID25059851
PMCPMC4182365
OpenAlexW2008340953

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.