ArticleAJNR. American journal of neuroradiology
"Y" and "X" stent-assisted coiling of complex and wide-neck intracranial bifurcation aneurysms.
Article in AJNR. American journal of neuroradiology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 65 papers, 7 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
65 citing papers in PubMed, 7 syntheses or guidelines pooled it.
- eCLIPs bifurcation remodeling system for treatment of wide-neck bifurcation aneurysms: A systematic review and meta-analysis of safety and efficacy.The neuroradiology journal · 2024Pooled it
- Efficacy and safety of low profile stents in Y-stent assisted coil embolization of wide-necked bifurcation aneurysms: a systematic review and meta-analysis.Neurosurgical review · 2024Pooled it
- Woven EndoBridge device for the treatment of ruptured intracranial aneurysms: A systematic review of clinical and angiographic results.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2022Pooled it
- Y-Stent-Assisted Coiling of Wide-Neck Bifurcation Intracranial Aneurysms: A Meta-Analysis.AJNR. American journal of neuroradiology · 2019Pooled it
- Treatment of Middle Cerebral Artery Aneurysms with Flow-Diverter Stents: A Systematic Review and Meta-Analysis.AJNR. American journal of neuroradiology · 2017Pooled it
- Endovascular Coiling of Wide-Neck and Wide-Neck Bifurcation Aneurysms: A Systematic Review and Meta-Analysis.AJNR. American journal of neuroradiology · 2016Pooled it
- Endovascular Treatment of Intracranial Aneurysms with the WEB Device: A Systematic Review of Clinical Outcomes.AJNR. American journal of neuroradiology · 2016Pooled it
- Feasibility of vault configuration of the Neuroform Atlas stent in the treatment of bifurcation intracranial aneurysm: clinical observation and hemodynamic simulation.Quantitative imaging in medicine and surgery · 2026Article
- Contour device implantation for treatment of intracranial aneurysms in the basilar tip.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026Article
- Comparison of flow diverters versus stent-assisted coiling in unruptured anterior circulation bifurcation aneurysms: a two-center, propensity score matched study.Neurosurgical review · 2026Article
- Deployment techniques and crossability of the EVO stent in wide-neck bifurcation aneurysms: AnInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025Article
- Delayed aneurysm occlusion after single stent-assisted coiling: factors in initially incompletely occluded unruptured intracranial aneurysms.Neurosurgical review · 2025Article
- Current research status and future of endovascular treatment for basilar artery aneurysms.The neuroradiology journal · 2024Review
- Stent plus balloon-assisted coiling with low-profile braided stents in the treatment of complex wide-necked intracranial bifurcation aneurysms.The neuroradiology journal · 2024Article
- Initial Experiences with the Trenza Embolization Device for the Treatment of Wide-Neck Intracranial Aneurysms: A 12-Patient Case Series.AJNR. American journal of neuroradiology · 2024Observational
- Current state of endovascular treatment of anterior cerebral artery aneurysms.Frontiers in neurology · 2024Review
- Single Neuroform Atlas stent: a reliable approach for treating complex wide-neck bifurcated aneurysms.Frontiers in neurology · 2024Article
- Safety and effectiveness of LEO stents for dual stent-assisted embolization combined with IA and IV intra-procedural infusion of tirofiban in the treatment of wide-necked intracranial bifurcation aneurysms.Frontiers in neurology · 2024Article
- Six-month Outcomes after PulseRider- and Conventional Single Stent-assisted Embolization for Bifurcation Aneurysms: A Propensity-adjusted Comparison.Neurologia medico-chirurgica · 2023Article
- Single centre experience of stent-assisted coiling of wide-necked basilar tip aneurysms.The British journal of radiology · 2023Article
5 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
background and purposeStent-assisted coiling with two stents has been described in some series for the treatment of complex and wide-neck bifurcation aneurysms. Our aim was to report our experience of a stent-assisted coiling technique with double stents in "Y" and "X" configurations, with emphasis on safety, feasibility, and efficacy. MATERIALS AND
methodsClinical and angiographic outcomes of patients for whom the strategic therapeutic option was the stent-assisted coiling technique in a Y or X configuration for neck scaffolding from June 2006 to June 2013 were retrospectively analyzed.
resultsOne hundred five aneurysms in 97 patients were treated during 100 consecutive procedures. There were 54.2% (57/105) MCA, 28.6% (30/105) anterior communicating artery, 16.2% (17/105) basilar tip, and 1.0% (1/105) ICA termination aneurysms. A Y stent placement was used to treat 87 aneurysms in 85 procedures; an X stent placement was used to treat 7 aneurysms in 6 procedures, while 9 procedures failed for 11 aneurysms. There were 10.0% (10/100) procedure-related permanent neurologic deficits and 1.0% (1/100) death. The immediate angiographic controls showed a complete occlusion in 47.6% (50/105) of the aneurysms and a partial (neck or sac remnant) occlusion in 52.4% (55/105). To date, 81.0% (85/105) of the aneurysms have been followed up (mean, 17 months) with angiography, disclosing a recanalization in 5.9% (5/85) and an improvement in 42.4% (36/85). At discharge and follow-up, the mRS score was 0 in 83.5% (81/97) of patients, 1 in 4.1% (4/97), 2 in 3.1% (3/97), 3 in 4.1% (4/97), 4 in 3.1% (3/97), and 6 in 2.1% (2/97).
conclusionsY and X stent-assisted coiling of complex and wide-neck intracranial bifurcation aneurysms is an effective technique.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials