Evidence map›Paper›PMID 25055382›Full record

ArticleIEEE transactions on medical imaging2014

Reducing multiplexing artifacts in multi-pinhole SPECT with a stacked silicon-germanium system: a simulation study.

Lindsay C Johnson, Sepideh Shokouhi, Todd E Peterson

Abstract read
In one paragraph

Article in IEEE transactions on medical imaging, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.5field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Lindsay C Johnson
Sepideh Shokouhi
Todd E Peterson
Vanderbilt University · US

Funding

Synthetic-Collimator SPECT with Semiconductor DetectorsR01EB013677 · NIBIB · VANDERBILT UNIVERSITY MEDICAL CENTER · PI PETERSON, TODD E · 2011 to 2014
$1.4M
In vivo Amyloid-Beta Imaging in Mouse Brain Using Stochastic Object ModelsR00EB009106 · NIBIB · VANDERBILT UNIVERSITY MEDICAL CENTER · PI SHOKOUHI, SEPIDEH · 2014 to 2016
$729k
NIBIB NIH HHS R00 EB009106NIBIB NIH HHS R01 EB013677NIBIB NIH HHS R01EB013677
6 · The paper itself

Abstract

In pinhole single photon emission computed tomography (SPECT), multi-pinhole collimators can increase sensitivity but may lead to projection overlap, or multiplexing, which can cause image artifacts. In this work, we explore whether a stacked-detector configuration with a germanium and a silicon detector, used with 123I (27-32, 159 keV), where little multiplexing occurs in the Si projections, can reduce image artifacts caused by highly-multiplexed Ge projections. Simulations are first used to determine a reconstruction method that combines the Si and Ge projections to maximize image quality. Next, simulations of different pinhole configurations (varying projection multiplexing) in conjunction with digital phantoms are used to examine whether additional Si projections mitigate artifacts from the multiplexing in the Ge projections. Reconstructed images using both Si and Ge data are compared to those using Ge data alone. Normalized mean-square error and normalized standard deviation provide a quantitative evaluation of reconstructed images' error and noise, respectively, and are used to evaluate the impact of the additional nonmultiplexed data on image quality. For a qualitative comparison, the differential point response function is used to examine multiplexing artifacts. Results show that in cases of highly-multiplexed Ge projections, the addition of low-multiplexed Si projections helps to reduce image artifacts both quantitatively and qualitatively.

Indexed as

ArtifactsAlgorithmsComputer SimulationGermaniumImage Processing, Computer-AssistedPhantoms, ImagingSiliconTomography, Emission-Computed, Single-PhotonGermaniumSilicon

Identifiers

PMID25055382
PMCPMC4565520
OpenAlexW2085153459

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.