ArticleJournal of biomechanics2014
Mechanical properties vary for different regions of the finger extensor apparatus.
Article in Journal of biomechanics, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Frictional instabilities as an alternative to friction coefficient in fine touch perception.eLife · 2026Article
- Assessment of the ligamentous stress distribution in the pathomechanics of the boutonniere deformity through a computational 3D model.Journal of orthopaedic surgery and research · 2025Article
- Decellularization of Human Digits: A Step Towards Off-the-Shelf Composite Allograft Transplantation.Bioengineering (Basel, Switzerland) · 2025Article
- Cosimulation of the index finger extensor apparatus with finite element and musculoskeletal models.Journal of biomechanics · 2023Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
The extensor apparatus, an aponeurosis that covers the dorsal side of each finger, transmits force from a number of musculotendons to the phalanges. Multiple tendons integrate directly into the structure at different sites and the extensor apparatus attaches to the phalanges at multiple points. Thus, prediction of the force distribution within the extensor apparatus, or hood, and the transmission to the phalanges is challenging, especially as knowledge of the underlying mechanical properties of the tissue is limited. We undertook quantification of some of these properties through material testing of cadaver specimens. We punched samples at specified locations from 19 extensor hood specimens. Material testing was performed to failure for each sample with a custom material testing device. Testing revealed significant differences in ultimate load, ultimate strain, thickness, and tangent modulus along the length of the extensor hood. Specifically, thickness, ultimate load, and ultimate strain were greater in the more proximal sections of the extensor hood, while the tangent modulus was greater in the more distal sections. The variations in mechanical properties within the hood may impact prediction of force transmission and, thus, should be considered when modeling the action of the extensor apparatus. Across the extensor hood, tangent modulus values were substantially smaller than values reported for other soft tissues, such as the Achilles tendon and knee ligaments, while ultimate strains were much greater. Thus, the tissue in the extensor apparatus seems to have greater elasticity, which should be modeled accordingly.