ReviewCritical care (London, England)2014
Continuous glucose control in the ICU: report of a 2013 round table meeting.
Review in Critical care (London, England), 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 47 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
47 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Perioperative use and accuracy of continuous glucose monitoring: A systematic review.Diabetes, obesity & metabolism · 2025Pooled it
- Real-time continuous glucose monitoring in preterm infants (REACT): an international, open-label, randomised controlled trial.The Lancet. Child & adolescent health · 2021Trial
- Accuracy and reliability of a subcutaneous continuous glucose monitoring device in critically ill patients.Journal of clinical monitoring and computing · 2018Trial
- Accuracy of 2 Different Continuous Glucose Monitoring Systems in Patients Undergoing Cardiac Surgery.Journal of diabetes science and technology · 2017Trial
- Pediatric Inpatient Continuous Glucose Monitor Accuracy by Sensor Wear Day, Hospital Day, and Glucose Rate of Change.Diabetes technology & therapeutics · 2026Article
- Continuous interstitial glucose monitoring in diabetic and non-diabetic critically ill patients is simple and accurate: comparison with venous, arterial and capillary glucose measurements.Acta diabetologica · 2025Observational
- Accuracy of a continuous glucose monitoring system applied before, during, and after an intense leg-squat session with low- and high-carbohydrate availability in young adults without diabetes.European journal of applied physiology · 2024Article
- Accuracy of a novel real-time continuous glucose monitoring system: a prospective self-controlled study in thirty hospitalized patients with type 2 diabetes.Frontiers in endocrinology · 2024Article
- Mean Blood Glucose Level During ICU Hospitalization is a Strong Predictor of the Mortality of COVID-19.Diabetes, metabolic syndrome and obesity : targets and therapy · 2024Article
- Analytical Performance of the Factory-Calibrated Flash Glucose Monitoring System FreeStyle Libre2Sensors (Basel, Switzerland) · 2023Article
- Observational
- The Accuracy of Continuous Glucose Monitoring in the Medical Intensive Care Unit.Journal of diabetes science and technology · 2022Article
- Machine-assisted nutritional and metabolic support.Intensive care medicine · 2022Article
- Semi-Implantable Bioelectronics.Nano-micro letters · 2022Review
- Subcutaneous continuous glucose monitoring in critically ill patients during insulin therapy: a meta-analysis.American journal of translational research · 2022Article
- Evaluation of a continuous glucose monitoring system in neonatal foals.Journal of veterinary internal medicine · 2021Article
- Safety and Accuracy of Factory-Calibrated Continuous Glucose Monitoring in Pediatric Patients Undergoing Hematopoietic Stem Cell Transplantation.Diabetes technology & therapeutics · 2020Observational
- Accuracy of Blood Glucose Measurement and Blood Glucose Targets.Journal of diabetes science and technology · 2020Review
- Accuracy and stability of an arterial sensor for glucose monitoring in a porcine model using glucose clamp technique.Scientific reports · 2020Article
- Dynamic properties of glucose complexity during the course of critical illness: a pilot study.Journal of clinical monitoring and computing · 2020Observational
Corrections and comments
- Commented on by
Authors and funding
17 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Achieving adequate glucose control in critically ill patients is a complex but important part of optimal patient management. Until relatively recently, intermittent measurements of blood glucose have been the only means of monitoring blood glucose levels. With growing interest in the possible beneficial effects of continuous over intermittent monitoring and the development of several continuous glucose monitoring (CGM) systems, a round table conference was convened to discuss and, where possible, reach consensus on the various aspects related to glucose monitoring and management using these systems. In this report, we discuss the advantages and limitations of the different types of devices available, the potential advantages of continuous over intermittent testing, the relative importance of trend and point accuracy, the standards necessary for reporting results in clinical trials and for recognition by official bodies, and the changes that may be needed in current glucose management protocols as a result of a move towards increased use of CGM. We close with a list of the research priorities in this field, which will be necessary if CGM is to become a routine part of daily practice in the management of critically ill patients.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.