ArticleDiabetes technology & therapeutics2014
Multicenter closed-loop insulin delivery study points to challenges for keeping blood glucose in a safe range by a control algorithm in adults and adolescents with type 1 diabetes from various sites.
Article in Diabetes technology & therapeutics, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 21 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
21 citing papers in PubMed, 1 synthesis or guideline pooled it, 47 citations in OpenAlex.
- Identification of Main Factors Explaining Glucose Dynamics During and Immediately After Moderate Exercise in Patients With Type 1 Diabetes.Journal of diabetes science and technology · 2015Pooled it
- Randomized Crossover Comparison of Automated Insulin Delivery Versus Conventional Therapy Using an Unlocked Smartphone with Scheduled Pasta and Rice Meal Challenges in the Outpatient Setting.Diabetes technology & therapeutics · 2020Trial
- Use of Sitagliptin With Closed-Loop Technology to Decrease Postprandial Blood Glucose in Type 1 Diabetes.Journal of diabetes science and technology · 2017Trial
- Adjustment of Open-Loop Settings to Improve Closed-Loop Results in Type 1 Diabetes: A Multicenter Randomized Trial.The Journal of clinical endocrinology and metabolism · 2015Trial
- Stress Testing of an Artificial Pancreas System With Pizza and Exercise Leads to Improvements in the System's Fuzzy Logic Controller.Journal of diabetes science and technology · 2015Trial
- Article
- Physical Activity, Dietary Patterns, and Glycemic Management in Active Individuals with Type 1 Diabetes: An Online Survey.International journal of environmental research and public health · 2021Article
- Factors Beyond Carbohydrate to Consider When Determining Meantime Insulin Doses: Protein, Fat, Timing, and Technology.Diabetes spectrum : a publication of the American Diabetes Association · 2020Article
- A Clinical Overview of Insulin Pump Therapy for the Management of Diabetes: Past, Present, and Future of Intensive Therapy.Diabetes spectrum : a publication of the American Diabetes Association · 2019Article
- Diabetes Technology: Monitoring, Analytics, and Optimal Control.Cold Spring Harbor perspectives in medicine · 2019Review
- The challenges of achieving postprandial glucose control using closed-loop systems in patients with type 1 diabetes.Diabetes, obesity & metabolism · 2018Review
- Automated closed-loop control of diabetes: the artificial pancreas.Bioelectronic medicine · 2018Review
- Remote Blood Glucose Monitoring in mHealth Scenarios: A Review.Sensors (Basel, Switzerland) · 2016Review
- A Review of Safety and Design Requirements of the Artificial Pancreas.Annals of biomedical engineering · 2016Review
- The Artificial Pancreas in 2016: A Digital Treatment Ecosystem for Diabetes.Diabetes care · 2016Article
- Is Psychological Stress a Factor for Incorporation Into Future Closed-Loop Systems?Journal of diabetes science and technology · 2016Article
- Psychological Reactions Associated With Continuous Glucose Monitoring in Youth.Journal of diabetes science and technology · 2016Review
- Artificial Pancreas Device Systems for the Closed-Loop Control of Type 1 Diabetes: What Systems Are in Development?Journal of diabetes science and technology · 2016Review
- Progress in Diabetes Technology: Developments in Insulin Pumps, Continuous Glucose Monitors, and Progress towards the Artificial Pancreas.The Journal of pediatrics · 2016Article
- Physical activity and type 1 diabetes: time for a rewire?Journal of diabetes science and technology · 2015Review
Corrections and comments
- Erratum issuedCorrection.2015 · Vistenin, Roberto [corrected to Visentin, Roberto]
Authors and funding
32 authors at 10 institutions in 5 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe Control to Range Study was a multinational artificial pancreas study designed to assess the time spent in the hypo- and hyperglycemic ranges in adults and adolescents with type 1 diabetes while under closed-loop control. The controller attempted to keep the glucose ranges between 70 and 180 mg/dL. A set of prespecified metrics was used to measure safety. RESEARCH DESIGN AND
methodsWe studied 53 individuals for approximately 22 h each during clinical research center admissions. Plasma glucose level was measured every 15-30 min (YSI clinical laboratory analyzer instrument [YSI, Inc., Yellow Springs, OH]). During the admission, subjects received three mixed meals (1 g of carbohydrate/kg of body weight; 100 g maximum) with meal announcement and automated insulin dosing by the controller.
resultsFor adults, the mean of subjects' mean glucose levels was 159 mg/dL, and mean percentage of values 71-180 mg/dL was 66% overall (59% daytime and 82% overnight). For adolescents, the mean of subjects' mean glucose levels was 166 mg/dL, and mean percentage of values in range was 62% overall (53% daytime and 82% overnight). Whereas prespecified criteria for safety were satisfied by both groups, they were met at the individual level in adults only for combined daytime/nighttime and for isolated nighttime. Two adults and six adolescents failed to meet the daytime criterion, largely because of postmeal hyperglycemia, and another adolescent failed to meet the nighttime criterion.
conclusionsThe control-to-range system performed as expected: faring better overnight than during the day and performing with variability between patients even after individualization based on patients' prior settings. The system had difficulty preventing postmeal excursions above target range.
Indexed as