ArticleJournal of veterinary internal medicine

ISO-based assessment of accuracy and precision of glucose meters in dogs.

Y Brito-Casillas, P Figueirinhas, J C Wiebe, L López-Ríos, D Pérez-Barreto, C Melián, A M Wägner

Abstract read
In one paragraph

Article in Journal of veterinary internal medicine. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Impact on result interpretation of correct and incorrect selection of veterinary glucometer canine and feline settings.Journal of veterinary diagnostic investigation : official publication of the American Association of Veterinary Laboratory Diagnosticians, Inc · 2023
    Article
  5. Article
  6. Comparison of glucose concentrations in canine whole blood, plasma, and serum measured with a veterinary point-of-care glucometer.Journal of veterinary diagnostic investigation : official publication of the American Association of Veterinary Laboratory Diagnosticians, Inc · 2021
    Article
  7. Article
  8. Article
  9. Accuracy of a Flash Glucose Monitoring System in Diabetic Dogs.Journal of veterinary internal medicine · 2016
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Y Brito-CasillasServicio de Endocrinología y Nutrición, Complejo Hospitalario Universitario Insular Materno Infantil de Gran Canaria, Las Palmas de Gran Canaria, Spain; Instituto Universitario de Investigaciones Biomédicas y Sanitarias, Universidad de Las Palmas de Gran Canaria, Las Palmas de Gran Canaria, Spain.
P Figueirinhas
J C Wiebe
L López-Ríos
D Pérez-Barreto
C Melián
A M Wägner

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPortable blood glucose meters (PBGMs) allow easy glucose measurements. As animal-specific PBGMs are not available everywhere, those for humans are widely used.

objectivesTo assess the accuracy and precision of 9 PBGMs in canine whole blood (WB) and plasma, based on the ISO 15197:2013. ANIMALS: Fifty-nine client-owned dogs attending the Veterinary Teaching Hospital.

methodsAnalytical evaluation of 100 blood samples was performed for accuracy and 23 for precision (glucose 29-579 mg/dL) following ISO recommendations. A PBGM was considered accurate if 95% of the measurements were within ±15 mg/dL from the reference when glucose was <100 mg/dL and within ±15% when it was ≥100 mg/dL, and if 99% of them were within zones A and B in error grid analysis (EG). A hexokinase-based analyzer was used as reference. Ninety samples were assessed for hematocrit interferences.

resultsAccuracy requirements were not fulfilled by any PBGM in WB (74% of measurements within the limits for the most accurate) and by 1 only in plasma. However, the EG analysis in WB was passed by 6 PBGM and by all in plasma. The most accurate were also the most precise, with coefficients of variation <5% in WB and <3% in plasma. Hematocrit correlated with bias against the reference method in 4 PBGM (r = -0.243 - [-0.371]; P < .021). CONCLUSIONS AND CLINICAL IMPORTANCE: This disparity among PBGM suggests that meters approved for humans need to be evaluated before use in other species.

Indexed as

AnimalsBlood GlucoseDog DiseasesDogsMonitoring, PhysiologicReference StandardsReproducibility of ResultsBlood GlucoseDiabetesDogISO 15197:2003ISO 15197:2013

Identifiers

PMID24990398
PMCPMC4895580

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.