Evidence map›Paper›PMID 24989381›Full record

ArticleMedical physics2014

A hybrid reconstruction algorithm for fast and accurate 4D cone-beam CT imaging.

Hao Yan, Xin Zhen, Michael Folkerts, Yongbao Li, Tinsu Pan, Laura Cervino, Steve B Jiang, Xun Jia

Abstract read
In one paragraph

Article in Medical physics, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Fast 4D cone-beam CT from 60 s acquisitions.Physics and imaging in radiation oncology · 2018
    Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Hao YanDepartment of Radiation Oncology, The University of Texas, Southwestern Medical Center, Dallas, Texas 75390.
Xin ZhenDepartment of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong 510515, China.
Michael FolkertsDepartment of Radiation Oncology, The University of Texas, Southwestern Medical Center, Dallas, Texas 75390.
Yongbao LiDepartment of Radiation Oncology, The University of Texas, Southwestern Medical Center, Dallas, Texas 75390 and Department of Engineering Physics, Tsinghua University, Beijing 100084, China.
Tinsu PanDepartment of Imaging Physics, The University of Texas, MD Anderson Cancer Center, Houston, Texas 77030.
Laura CervinoDepartment of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California 92093.
Steve B JiangDepartment of Radiation Oncology, The University of Texas, Southwestern Medical Center, Dallas, Texas 75390.
Xun JiaDepartment of Radiation Oncology, The University of Texas, Southwestern Medical Center, Dallas, Texas 75390.

Funding

Low dose cone beam CT for image guided adaptive radiotherapyR01CA154747 · NCI · UT SOUTHWESTERN MEDICAL CENTER · PI JIANG, STEVE BIN · 2011 to 2015
$1.4M
NCI NIH HHS 1R01CA154747-01NCI NIH HHS R01 CA154747
6 · The paper itself

Abstract

purpose4D cone beam CT (4D-CBCT) has been utilized in radiation therapy to provide 4D image guidance in lung and upper abdomen area. However, clinical application of 4D-CBCT is currently limited due to the long scan time and low image quality. The purpose of this paper is to develop a new 4D-CBCT reconstruction method that restores volumetric images based on the 1-min scan data acquired with a standard 3D-CBCT protocol.

methodsThe model optimizes a deformation vector field that deforms a patient-specific planning CT (p-CT), so that the calculated 4D-CBCT projections match measurements. A forward-backward splitting (FBS) method is invented to solve the optimization problem. It splits the original problem into two well-studied subproblems, i.e., image reconstruction and deformable image registration. By iteratively solving the two subproblems, FBS gradually yields correct deformation information, while maintaining high image quality. The whole workflow is implemented on a graphic-processing-unit to improve efficiency. Comprehensive evaluations have been conducted on a moving phantom and three real patient cases regarding the accuracy and quality of the reconstructed images, as well as the algorithm robustness and efficiency.

resultsThe proposed algorithm reconstructs 4D-CBCT images from highly under-sampled projection data acquired with 1-min scans. Regarding the anatomical structure location accuracy, 0.204 mm average differences and 0.484 mm maximum difference are found for the phantom case, and the maximum differences of 0.3-0.5 mm for patients 1-3 are observed. As for the image quality, intensity errors below 5 and 20 HU compared to the planning CT are achieved for the phantom and the patient cases, respectively. Signal-noise-ratio values are improved by 12.74 and 5.12 times compared to results from FDK algorithm using the 1-min data and 4-min data, respectively. The computation time of the algorithm on a NVIDIA GTX590 card is 1-1.5 min per phase.

conclusionsHigh-quality 4D-CBCT imaging based on the clinically standard 1-min 3D CBCT scanning protocol is feasible via the proposed hybrid reconstruction algorithm.

Indexed as

AlgorithmsComputersCone-Beam Computed TomographyFeasibility StudiesFour-Dimensional Computed TomographyHumansImage Processing, Computer-AssistedModels, TheoreticalMotionPhantoms, ImagingTime Factors

Identifiers

PMID24989381
PMCPMC4187347

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.