Evidence map›Paper›PMID 24986761›Full record

ArticleMedical science monitor : international medical journal of experimental and clinical research2014

Endovascular coil embolization of aneurysm neck for the treatment of ruptured intracranial aneurysm with bleb formation.

Jun Wan, Weijin Gu, Xiaolong Zhang, Daoying Geng, Gang Lu, Lei Huang, Lei Zhang, Liang Ge, Lihua Ji

Open access · hybridAbstract read
In one paragraph

Article in Medical science monitor : international medical journal of experimental and clinical research, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.2field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Management of Extracranial Carotid Artery Aneurysms: A 6-Year Case Series.Medical science monitor : international medical journal of experimental and clinical research · 2019
    Article
  4. Clinical Study on Complications of Intracranial Ruptured Aneurysm Embolization by Stent-Assisted Coil.Medical science monitor : international medical journal of experimental and clinical research · 2018
    Article
  5. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Jun WanDepartment of Radiology, Jing'an District Centre Hospital of Shanghai Huashan Hospital Fudan University Jing'an Branch, Shanghai, China (mainland).
Weijin GuDepartment of Radiology, Jing'an District Centre Hospital of Shanghai Huashan Hospital Fudan University Jing'an Branch, Shanghai, China (mainland).
Xiaolong ZhangDepartment of Radiology, Huashan Hospital, Fudan University, Shanghai, China (mainland).
Daoying GengDepartment of Radiology, Huashan Hospital, Fudan University, Shanghai, China (mainland).
Gang LuDepartment of Radiology, Huashan Hospital, Fudan University, Shanghai, China (mainland).
Lei HuangDepartment of Radiology, Huashan Hospital, Fudan University, Shanghai, China (mainland).
Lei ZhangDepartment of Radiology, Jing'an District Centre Hospital of Shanghai Huashan Hospital Fudan University Jing'an Branch, Shanghai, China (mainland).
Liang GeDepartment of Radiology, Huashan Hospital, Fudan University, Shanghai, China (mainland).
Lihua JiDepartment of Radiology, Jing'an District Centre Hospital of Shanghai Huashan Hospital Fudan University Jing'an Branch, Shanghai, China (mainland).
Fudan University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRuptured intracranial aneurysm (ICA) with bleb formation (RICABF) is a special type of ruptured ICA. However, the exact role and effectiveness of endovascular coil embolization (ECE) in RICABF is unknown. We aimed to investigate the effectiveness and safety of ECE of aneurysm neck for RICABF treatment. MATERIAL AND

methodsWe retrospectively assessed consecutive patients who were hospitalized in our endovascular intervention center between October 2004 and May 2012. Overall, 86 patients underwent ECE of aneurysm neck for 86 RICABF. Treatments outcomes included secondary rupture/bleeding rate, aneurysm neck embolization rate, residual/recurrent aneurysm, intraoperative incidents, and post-embolization complications, as well as improvements in the Glasgow outcome scale (extended) (GOS-E).

resultsComplete occlusion was achieved in 72 aneurysms (72/86, 83.7%), while 12 aneurysms (12/86, 14.0%) had a residual neck, and 2 aneurysms (2/86, 2.3%) had a residual aneurysm. The postoperative GOS-E was 3 in 3 patients (3.5%), 4 in 10 patients (11.6%), and 5 in 73 patients (84.9%). Follow-up angiography was performed in all patients (mean 9.0 months, interquartile range of 9.0). Recurrence was found in 3 patients (3/86, 3.5%). No aneurysm rupture or bleeding was reported.

conclusionsOur mid-term follow-up study showed that ECE of aneurysm neck was an effective and safe treatment modality for RICABF. The long-term effectiveness and safety of this interventional radiology technique need to be investigated in prospective and comparative studies.

Indexed as

Embolization, TherapeuticEndovascular ProceduresAdultAneurysm, RupturedBlisterFemaleFollow-Up StudiesHumansIntracranial AneurysmMaleMiddle AgedPostoperative ComplicationsSubarachnoid HemorrhageTomography, X-Ray ComputedTreatment Outcome

Identifiers

PMID24986761
PMCPMC4095703
OpenAlexW2044394410

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.