Considering angle selection when using ultrasound electrode displacement elastography to evaluate radiofrequency ablation of tissues.

Jingjing Xia, Qiang Li, Pin-Yu Chen, Zhuhuang Zhou, Chiao-Yin Wang, Hao-Li Liu, Jianfu Teng, Po-Hsiang Tsui

Open access · hybridAbstract read
In one paragraph

Article in BioMed research international, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.3field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Jingjing XiaSchool of Electronic Information Engineering, Tianjin University, Tianjin 300072, China.ORCID 0000-0002-6629-8554
Qiang LiSchool of Electronic Information Engineering, Tianjin University, Tianjin 300072, China.
Pin-Yu ChenDepartment of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, 259 Wen-Hwa 1st Road, Kwei-Shan, Taoyuan, Taoyuan County 33302, Taiwan.
Zhuhuang ZhouBiomedical Engineering Center, College of Life Science and Bioengineering, Beijing University of Technology, Beijing 100124, China.ORCID 0000-0003-0570-8473
Chiao-Yin WangDepartment of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, 259 Wen-Hwa 1st Road, Kwei-Shan, Taoyuan, Taoyuan County 33302, Taiwan ; Graduate Institute of Clinical Medical Sciences, College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan.
Hao-Li LiuDepartment of Electrical Engineering, Chang Gung University, Taoyuan 33302, Taiwan.
Jianfu TengSchool of Electronic Information Engineering, Tianjin University, Tianjin 300072, China.
Po-Hsiang TsuiDepartment of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, 259 Wen-Hwa 1st Road, Kwei-Shan, Taoyuan, Taoyuan County 33302, Taiwan ; Institute for Radiological Research, Chang Gung Memorial Hospital at Linkou, Chang Gung University, Taoyuan 33302, Taiwan.ORCID 0000-0002-5604-1800
Chang Gung University · TWTianjin University · CNBeijing University of Technology · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Percutaneous radiofrequency ablation (RFA) is a minimally invasive treatment to thermally destroy tumors. Ultrasound-based electrode-displacement elastography is an emerging technique for evaluating the region of RFA-induced lesions. The angle between the imaging probe and the RFA electrode can influence electrode-displacement elastography when visualizing the ablation zone. We explored the angle effect on electrode-displacement elastography to measure the ablation zone. Phantoms embedded with meatballs were fabricated and then ablated using an RFA system to simulate RFA-induced lesions. For each phantom, a commercial ultrasound scanner with a 7.5 MHz linear probe was used to acquire raw image data at different angles, ranging from 30° to 90° at increments of 10°, to construct electrode-displacement images and facilitate comparisons with tissue section images. The results revealed that the ablation regions detected using electrode-displacement elastography were highly correlated with those from tissue section images when the angle was between 30° and 60°. However, the boundaries of lesions were difficult to distinguish, when the angle was larger than 60°. The experimental findings suggest that angle selection should be considered to achieve reliable electrode-displacement elastography to describe ablation zones.

Indexed as

AlgorithmsCatheter AblationElasticity Imaging TechniquesElectrodesPhantoms, ImagingUltrasonics